Cisco 2010 Connected Grid Router is a rugged router optimized for use in transmission & phân bổ (T&D) power substations, and It provides operators with the benefits of improved security, manageability, and network reliability. Ngoài ra, the Cisco 2010 Connected Grid Router is designed for substation networks to meet the harsh environments common in transmission & distribution substations.

Cisco 2010 Connected Grid Router Overview

Cisco 2010 Connected Grid Router builds on the award-winning Integrated Services Router G2 (ISR G2) platform, and it delivers high-quality routing, bảo vệ, sự quản lý, and network intelligence. Cisco 2010 Connected Grid Router provides integrated security to protect energy-related communication networks. This model complies with cybersecurity requirements such as the NERC/CIP mandates. Ngoài ra, the platform supports T1/E1 WAN interfaces with integrated CSU/DSU interfaces, synchronous and asynchronous serial RS-232 interfaces, and copper and fiber Gigabit Ethernet

Cisco 2010 Connected Grid Router Product Picture

Cisco 2010 Bộ định tuyến lưới được kết nốiCisco 2010 Bộ định tuyến lưới được kết nối

Cisco 2010 Bộ định tuyến lưới được kết nốiCisco 2010 Bộ định tuyến lưới được kết nối

Cisco 2010 Connected Grid Router Specifications

characteristic Sự chỉ rõ
Substation hardening compliance IEC 61850-3 IEEE1613
Embedded hardware-based cryptography acceleration (IPSec + SSL) Đúng
Total onboard Combo Ethernet WAN Ports 2
Grid Router WAN Interface Card (GRWIC) khe cắm 4
Double-wide capable GRWIC slots (use of a double- wide GRWIC slot will consume two GRWIC slots) 2
Memory DDR2 ECC DRAM – mặc định 1 GB
Rugged compact flash chỗ 0: 256 MB (Mặc định)
chỗ 1: 256 MB (Optional Expansion for storage)
External USB 2.0 flash memory slots (Loại A) 2
USB Console port (Loại B) (lên đến 115.2 kbps) 1
Cổng giao diện điều khiển nối tiếp 1
Serial auxiliary port 1
Power supply options Two power supply options:
Low-voltage DC power supply (available in late 2010)
AC or high-voltage DC power supply
Any combination of power supplies can be inserted into the chassis. Dual power supply configurations are load sharing in redundancy mode, although a single power supply is sufficient for supporting power needs for the system.
Thông số nguồn
Điện áp đầu vào AC (Power Supply Unit 1) Nominal Range: 100 – 240 VAC
Operating Range: 85 -264 VAC
AC supply also accepts a DC input with an operating range of 88 – 300 VDC
DC input voltage (Power Supply Unit 2) Nominal Range: 24 – 60 VDC
Operating Range: 20 – 75 VDC
AC input frequency 47 ĐẾN 63 Hz
AC input current range for AC power supply (tối đa) 2:00 LÀ
AC input surge current <50 MỘT
DC input voltage 24 – 60 VDC, extended 88-300 VDC (on separate power supply)
System power consumption (with no modules) (Watt) 30 Watt
Grid Router WIC power consumption Đặc trưng: 4.5 Watts Maximum: 6 Watt
Thông số vật lý
Kích thước (Cao x Rộng x D) 3.5 x 17.25 x 15 TRONG. (88.9 x 438.2 x 381 mm)
Chiều cao giá 2 RU (rack unit)
Rack-mount 19 TRONG. (48.3 cm) EIA Included
Wall-mount Đúng
Weight with 1 Nguồn cấp (no modules) 19 pound (8.6Kilôgam)
Typical weight fully configured with 2 power supplies and 4 GRWICs 25 pound (11.4 Kilôgam)
Luồng khí Convection and conduction cooling (không có người hâm mộ)
Thông số kỹ thuật môi trường
Operating Conditions
Nhiệt độ hoạt động -40 ºF to 140ºF (-40 to +60ºC) continuous operating temperature range
-40 ºF to 185ºF (-40 to +85ºC) type test for 100 hours at 85ºC
Shock/Vib 30G @11 ms
Độ cao 10,000 ft (3,048 tôi) Max operating temp is de-rated with increasing altitude per IEEE 1613-2009
Độ ẩm tương đối 5 ĐẾN 95% không ngưng tụ
Non-operating conditions
Nhiệt độ -40ºF to 185ºF (-40ºC to 85ºC)
Độ ẩm tương đối 5 ĐẾN 95% không ngưng tụ
Độ cao 16,000 ft (4,876 tôi) Max operating temp is de-rated with increasing altitude per IEEE 1613a-2008
Non-Op Free Fall Drop 4 TRONG. (100 mm) per ENG-339611
Operating seismic/earthquake NEBS GR-63 (5.4.1)
Non-op shock/vib 40-50G (3.26 m/s minimum)

Cisco 2010 Bộ định tuyến lưới được kết nối

Integrated Network Security

Network security is important to the reliability of an energy network. Operators must help ensure that data communications used to operate the energy infrastructure are prioritized and are not affected by cyber attacks. Cisco created a suite of security features designed to help ensure the integrity of grid communications.

Cisco 2010 Connected Grid Router offers onboard hardware-based encryption acceleration to provide greater IPSec throughput with less overhead for the route processor when compared with software-based encryption solutions. Cisco 2010 Connected Grid Router offers a comprehensive and adaptable security solution for energy networks

Combination Gigabit Ethernet Ports

Cisco 2010 Connected Grid Router supports two on-board Combo (RJ45 for copper or SFP for fiber) Gigabit Ethernet interfaces for WAN and LAN connectivity. Both Layer 2 và lớp 3 (IP routing) features are supported on these interfaces for maximum flexibility. The GCR 2010 smoothly combines industry-leading security, Cisco IOS Software-based traffic control, and visibility with Cisco application acceleration solutions.

Managing Connected Grid Router

Network management applications are instrumental in lowering operating expenses (OpEx), while improving network availability by simplifying and automating many of the day-to-day tasks associated with managing an end-to-end network. Day-one device support provides immediate manageability support for the CGR 2010, enabling quick and easy deployment, giám sát, and troubleshooting from Cisco and third-party applications.





    Lấy làm tiếc, không có tệp đính kèm nào !