- Beskrivning
- Förfrågan
- Anknytning
Beskrivning
Huawei S12708 Switch features 4.88/16.08 Tbit/s Switching Capacity 12.32/44.96 Tbit/s Packet Forwarding Rate 2 MPU Slots 4 SFU Slots 6 Service Card Slots
Huawei S12708 Switch Product Overview
Huawei S12708 Switch is designed for next-generation campus networks, which uses a fully programmable architecture to meet fast-changing service needs. Huawei S12708 Switch allows new services to be flexibly and quickly provisioned in six months. Huawei S12708 Switch provides high-performance Layer 2/Layer3 switching services, supports millions of hardware entries, and can meet campus network evolution over the next 10 år. Huawei S12708 Switch has built-in large-capacity WLAN AC functionalities, achieving wired and wireless convergence and eliminating the capacity bottleneck of ACs.
Huawei S12708 Switch Product Pictures
Huawei S12708 Switch Product Specifications
Artikel | S12704 | S12708 | S12710 | S12712 |
Växlingskapacitet | 4.88Tbps/16.08*Tbps | 12.32Tbps/44.96*Tbps | 13.12Tbps/38.56*Tbps | 17.44Tbps/44.96*Tbps |
Paketöverföringshastighet | 3, 120Mpps/4, 560*Mps | 6, 240Mpps/30, 240*Mps | 7, 440Mpps/11, 040*Mps | 9, 120Mpps/30, 240*Mps |
MPU slots | 2 | 2 | 2 | 2 |
SFU slots | 2 | 4 | 4 (2 integrated in MPU) | 4 |
Service card slots | 4 | 8 | 10 | 12 |
Fan slots | 2 | 4 | 4 | 5 |
Buffer size | 200ms buffer each port | |||
Redundancy design | MPU:er, SFU:er, nätaggregat, and fan modules | |||
CSS2 | 1+N backup of MPUs in a cluster | |||
Upp till 1.92 Tbit/s cluster bandwidth, 4 μs inter-chassis transmission latency | ||||
Mått (H x W x D in mm) | 441.7x442x489, 10U | 663.95x442x489, 15U | 663.95x442x489, 15U | 841.75x442x489, 19U |
Vikt (empty chassis) | 24.5kg | 42kg | 28.6kg | 64kg |
Driftspänning | DC:–40V~–72V | |||
AC:90V~290V | ||||
Maximum power consumption of the entire equipment | ≤2200W | ≤4400W | ≤4400W | ≤6600W |
Huawei S12708 Switch Product Features
OPS
Öppna programmerbarhetssystem (OPS) är ett öppet programmerbart system baserat på Python-språket. IT administrators can program the O&M functions of a switch through Python scripts to quickly innovate functions and implement intelligent O&M.
Big data security collaboration
Agile switches use NetStream to collect campus network data and then report such data to the Huawei Cybersecurity Intelligence System (CIS). The purposes of doing so are to detect network security threats, display the security posture across the entire network, and enable automated or manual response to security threats. The CIS delivers the security policies to the Agile Controller. The Agile Controller then delivers such policies to agile switches that will handle security events accordingly. All these ensure campus network security.
Intelligent diagnosis
Open Intelligent Diagnosis System (OIDS) integrates the device health monitoring and fault diagnosis functions – that are typically deployed on a Network Management System (NMS) – into the switch software to implement intelligent diagnosis on a single switch. After OIDS is deployed on a switch, the switch periodically collects and records the running information and automatically determines whether a fault occurs. If a fault occurs, the switch automatically locates the fault or helps locate the fault. All these merits increase fault locating efficiency of O&M staff while improving device maintainability.
Huawei S12708 Switch Product Ordering Info
LE2BN66ED000 | N66E DC assembly rack (åtta 60A utgångar, maximum 2,200W per output, 600 x 600 x 2,200 mm) |
LE2BN66EA000 | N66E AC assembly rack (four 16A outputs, maximum 2,500W per output, 600 x 600 x 2,200 mm) |
ET1BS12704S0 | S12704 Assembly Chassis |
ET1BS12708S0 | S12708 assembly chassis |
ET1BS12710S0 | S12710 assembly chassis |
ET1BS12712S0 | S12712 assembly chassis |
ET1MFBX00000 | Wide Voltage 129 Fan Box |
EH1M00FBX000 | Wide Voltage 74 Fan Box |
Övervakningsenhet | |
EH1D200CMU00 | Centralized monitoring unit |
Main processing unit | |
ET1D2MPUA000 | S12700 main control unit A, optional clock |
ET1D2MPUBC00 | S12710 main control unit B, optional clock |
ET1D2MPUBC01 | S12710,Main Processing Unit B (supports Secure Boot) |
ET1D2MPUDC00 | S12704/S12708/S12712, main processing unit D |
Switch fabric unit | |
ET1D2SFUA000 | S12700 switch fabric unit A |
ET1D2SFUB000 | S12700 switch fabric unit B |
ET1D2SFUC000 | S12700 switch fabric unit C |
ET1D2SFUD000 | S12700 switch fabric unit D |
100M/1,000M Ethernet electrical interface cards | |
ET1D2G48TEA0 | 48-hamn 10/100/1,000 BASE-T interface card (EA, RJ45) |
ET1D2G48TEC0 | 48-hamn 10/100/1,000 BASE-T interface card (EC, RJ45) |
ET1D2G48TX1E | 48-hamn 10/100/1,000 BASE-T interface card (X1E, RJ45) |
ET1D2G48TX5S | 48-port 100/1000BASE-T interface card (X5S, RJ45) |
ET1D2G48TX5E | 48-port 100/1000BASE-T interface card (X5E, RJ45) |
ET1D2G48TX5H | 48-port 100/1000BASE-T interface card (X5H, RJ45) |
100M/1,000M Ethernet optical interface cards | |
ET1D2G24SEC0 | 24-hamn 100/1,000 BASE-X interface card (EC, SFP) |
ET1D2G24SX5E | 24-port 100/1000BASE-X interface card (X5E, SFP) |
ET1D2G48SEA0 | 48-hamn 100/1,000 BASE-X interface card (EA, SFP) |
ET1D2G48SEC0 | 48-hamn 100/1,000 BASE-X interface card (EC, SFP) |
ET1D2G48SX1E | 48-hamn 100/1,000 BASE-X interface card (X1E, SFP) |
ET1D2G48SX5S | 48-port 100/1000BASE-X interface card (X5S, SFP) |
ET1D2G48SX5E | 48-port 100/1000BASE-X interface card (X5E, SFP) |
ET1D2G48SX5H | 48-port 100/1000BASE-X interface card (X5H, SFP) |
100M/1,000M Ethernet electrical and optical interface cards | |
ET1D2T36SEA0 | 36-hamn 10/100/1000 BASE-T and 12-port 100/1000 BASE-X interface card (EA, RJ45/SFP) |
10 GE optical interface cards | |
ET1D2S04SX1E | 4-port 10G BASE-X and 24-port 100/1000 BASE-X and 8-port 10/100/1000 BASE-T combo interface card (X1E, RJ45/SFP/SFP+) |
ET1D2S04SX5E | 4-port 10GE SFP+ and 44-port GE SFP interface card (X5E, SFP+) |
ET1D2S08SX1E | 8-port 10G BASE-X and 8-port 100/1000 BASE-X and 8-port 10/100/1000 BASE-T combo interface card (X1E, RJ45/SFP/SFP+) |
ET1D2X08SX5E | 8-port 10GE SFP+ gränssnittskort (X5E, SFP+) |
ET1D2X08SX5H | 8-port 10GE SFP+ gränssnittskort (X5H, SFP+) |
ET1D2X16SSC2 | 16-Port 10GBASE-X Interface Card(SC, SFP+) |
ET1D2X32SSC0 | 32-Port 10GBASE-X Interface Card(SC, SFP+) |
ET1D2X48SEC0 | 48-port 10G BASE-X interface card (EC, SFP+) |
ET1D2X32SX2H | 32-Port 10GE SFP+ Interface Card(X2H, SFP+) |
ET1D2X32SX2S | 32-Port 10GE SFP+ Interface Card(X2S, SFP+) |
ET1D2X32SX2E | 32-Port 10GE SFP+ Interface Card(X2E, SFP+) |
ET1D2S24SX2S | 24-Port 10GE SFP+ Interface and 8-Port GE SFP Interface Card(X2S, SFP+) |
ET1D2S24SX2E | 24-Port 10GE SFP+ Interface and 8-Port GE SFP Interface Card(X2E, SFP+) |
ET1D2S16SX2S | 16-Port 10GE SFP+ Interface and 16-Port GE SFP Interface Card(X2S, SFP+) |
ET1D2S16SX2E | 16-Port 10GE SFP+ Interface and 16-Port GE SFP Interface Card(X2E, SFP+) |
ET1D2X48SX2S | 48-Port 10GE SFP+ Interface Card(X2S, SFP+) |
40 GE optical interface cards | |
ET1D2L02QSC0 | 2-port 40G BASE-X interface card (SC, QSFP+) |
ET1D2L08QSC0 | 8-port 40G BASE-X interface card (SC, QSFP+) |
EH1D2L08QX2E | 8-Hamn 40 GE QSFP+ Interface Card (X2E, QSFP+) |
ET1D2L16QX2H | 16-Hamn 40 GE QSFP+ Interface Card (X2H, QSFP+) |
100 GE optical interface cards | |
ET1D2C02FEE0 | 2-Port 100G BASE-X Interface Card(EE,CFP) |
ET1D2C04HX2H | 4-Hamn 100 GE QSFP28 Interface Card (X2H, QSFP28) |
ET1D2C04HX2S | 4-Hamn 100 GE QSFP28 Interface Card (X2S, QSFP28) |
ET1D2C04HX2E | 4-Hamn 100 GE QSFP28 Interface Card (X2E, QSFP28) |
ET1D2C08HX2H | 8-Hamn 100 GE QSFP28 Interface Card (X2H, QSFP28) |
ET1D2H02QX2S | 2-Hamn 100 GE QSFP28 Interface and 2-Port 40 GE QSFP+ Interface Card (X2S, QSFP28) |
ET1D2H02QX2E | 2-Hamn 100 GE QSFP28 Interface and 2-Port 40 GE QSFP+ Interface Card (X2E, QSFP28) |
Service subcards | |
EH1D2VS08000 | 8-port 10G cluster switching system service unit (SFP+) |
ET1D2VQ06000 | 6-Hamn 40 GE Cluster Switching System Service Unit (QSFP+) |
LE0D00CKMA00 | Clock Pinch Board-1588 |
Service processing cards | |
ET1D2FW00S00 | NGFW Module A, with HW General Security Platform Software |
ET1D2FW00S01 | NGFW Module B, with HW General Security Platform Software |
ET1D2FW00S02 | NGFW Module C, with HW General Security Platform Software |
ET1D2IPS0S00 | IPS Module A, with HW General Security Platform Software |
ACU2 | WLAN ACU2 Access Controller Unit (128 AP Control Resource Included) |
Optical transceivers | |
FE-SFP optical transceiver | |
SFP-FE-SX-MM1310 | Optisk transceiver, SFP, 100M/155M, Multi-mode Module (1,310 nm, 2 km, LC) |
eSFP-FE-LX-SM1310 | Optisk transceiver, eSFP, 100M/155M, Single-mode Module (1,310 nm, 15 km, LC) |
S-SFP-FE-LH40-SM1310 | Optisk transceiver, eSFP, FE, single-mode module (1,310 nm, 40 km, LC) |
S-SFP-FE-LH80-SM1550 | Optisk transceiver, eSFP, FE, single-mode module (1,550 nm, 80 km, LC) |
GE-SFP optical transceiver | |
SFP-1000BaseT | Copper transceiver, SFP, GE, electrical interface module (100m, RJ45) |
eSFP-GE-SX-MM850 | Optisk transceiver, eSFP, GE, multimode module (850 nm, 0.5 km, LC) |
SFP-GE-LX-SM1310 | Optisk transceiver, SFP, GE, single-mode module (1,310 nm, 10 km, LC) |
S-SFP-GE-LH40-SM1310 | Optisk transceiver, eSFP, GE, single-mode module (1,310 nm, 40 km, LC) |
S-SFP-GE-LH40-SM1550 | Optisk transceiver, eSFP, GE, single-mode module (1,550 nm, 40 km, LC) |
S-SFP-GE-LH80-SM1550 | Optisk transceiver, eSFP, GE, single-mode module (1,550 nm, 80 km, LC) |
eSFP-GE-ZX100-SM1550 | Optisk transceiver, eSFP, GE, single-mode module (1,550 nm, 100 km, LC) |
10 GE-XFP Optical transceiver | |
XFP-SX-MM850 | Optisk transceiver, XFP, 10G, multimode module (850 nm, 0.3 km, LC) |
XFP-STM64-LX-SM1310 | Optisk transceiver, XFP, 10G, single-mode module (1,310 nm, 10 km, LC) |
XFP-STM64-LH40-SM1550 | Optisk transceiver, XFP, 10G, single-mode module (1,550 nm, 40 km, LC) |
XFP-STM64-SM1550-80 km | Optisk transceiver, XFP, 10G, single-mode module (1,550 nm, 80 km, LC) |
10 GE-SFP+ Optical transceiver | |
OMXD30000 | Optisk transceiver, SFP+, 10G, multimode module (850 nm, 0.3 km, LC) |
OSX010000 | Optisk transceiver, SFP+, 10G, single-mode module (1,310 nm, 10 km, LC) |
OSX040N01 | Optisk transceiver, SFP+, 10G, single-mode module (1,550 nm, 40 km, LC) |
OSXD22N00 | Optisk transceiver, SFP+, 10G, single-mode module (1,310 nm, 0.22km, LC, LRM) |
SFP-10G-USR | Optisk transceiver, SFP+, 10G, multimode module (850 nm, 0.1 km, LC) |
SFP-10G-ZR | Optisk transceiver, SFP+, 10G, single-mode module (1,550 nm, 80 km, LC) |
SFP-10G-ZCW1571 | Optisk transceiver, SFP+, 10G, single-mode module (CWDM, 1,571 nm, 70 km, LC) |
SFP-10G-ZCW1591 | Optisk transceiver, SFP+, 10G, single-mode module (CWDM, 1,591 nm, 70 km, LC) |
SFP-10G-ZCW1611 | Optisk transceiver, SFP+, 10G, single-mode module (CWDM, 1,611 nm, 70 km, LC) |
SFP-10G-iLR | Optisk transceiver, SFP+, 10G, single-mode module (DWDM, 1560.61–1529.16nm, 60km, LC) |
SFP-10G-ZDWT-L | Optical Transceiver, SFP+, 9.8G, Single-mode Module (1,310 nm, 1.4 km, LC) |
40 GE optical transceivers | |
QSFP-40G-iSR4 | 40G Base-iSR4 Optical transceiver, QSFP, 40G, multimode module (850 nm, 0.15 km, MPO) (connecting to four SFP+ optical transceivers) |
QSFP-40G-LX4 | 40G Base-LX4 Optical Transceiver, QSFP+, 40 GE, Singelläge (1,310 nm, 2 km, LC), Multi-mode (1,310 nm, 0.15 km, LC) |
QSFP-40G-iSM4 | 40G Base-iSM4 Optical Transceiver, QSFP+, 40G, Single-mode Module (1,310 nm, 1.4 km, MPO) (connecting to four SFP+ optical transceivers) |
QSFP-40G-eSM4 | 40G Base-eSM4 Optical Transceiver, QSFP+, 40G, Single-mode Module (,1310 nm, 10 km, MPO) (connecting to four SFP+ optical transceivers) |
QSFP-40G-LR4 | 40G Base-LR4 optical transceiver, QSFP+, 40G, single-mode module (1,310 nm, 10 km, LC) |
QSFP-40G-eSR4 | 40G Base-eSR4 Optical transceiver, QSFP+, 40G, multimode module (850 nm, 0.3 km, MPO) (connecting to four SFP+ optical transceivers) |
CFP-40G-SR4 | High-Speed Transceiver, CFP, 40G, Multimode Module (850 nm, 4 x 10G, 0.1 km, MPO) |
CFP-40G-LR4 | High-Speed Transceiver, CFP, 40G, Single-mode Module (1,310 nm band, 41.25G, 10 km, stright LC) |
CFP-40G-ER4 | High-Speed Transceiver, CFP, 40G, Single-mode Module (1,310 nm band, 41.25G, 40 km, stright LC) |
CFP-40G-ZR4 | High-Speed Transceiver, CFP,40G, Single-mode Module (1,550 nm band, 41.25G, 80 km, stright LC) |
QSFP-40G-ER4 | 40G Base-ER4 Optical Transceiver, QSFP+, 40G, Single-mode Module (1,310 nm, 40 km, LC) |
100 GE optical transceivers | |
CFP-100G-SR10 | High-Speed Transceiver, CFP, 100G, Multimode Module (850 nm, 10 x 10G, 0.1 km, MPO) (can connect to 10 SFP+ ports or 2 QSFP+ ports) |
CFP-100G-LR4 | High-Speed Transceiver, CFP, 100G, Single-mode Module (1,310 nm band, 4 x 25G, 10 km, stright LC) |
CFP-100G-ER4 | High-Speed Transceiver, CFP, 100G, Single-mode Module (1,310 nm band, 4 x 25G, 40 km, stright LC) |
CFP-100GE-ZR4 | 100G Base,CFP Module, 100G, Single-mode Module (1,310 nm band, 4 x 25G, 80 km, stright LC) |
QSFP-100G-CLR4 | High-Speed Transceiver, QSFP28, 1,310 nm, 4 x 25G Base, -6.5 dBm, 2.5 dBm, -10.7 dBm, LC/PC, 2 km |
QSFP-100G-CWDM4 | High-Speed Transceiver, QSFP28, 1,310 nm, 4 x 25G Base, -6.5 dBm, 2.5 dBm, -9.8 dBm, LC/PC, 2 km |
QSFP-100G-ER4-Lite | 100G Base-ER4-Lite Optical Transceiver, QSFP28, 100G, Single-mode modul (1,310 nm, 30 km (FEC AV), 40 km (FEC PÅ), LC) |
QSFP-100G-LR4 | 100G Base-LR4 Optical Transceiver, QSFP28, 100G, Single-mode modul (1,310 nm, 10 km, LC) |
QSFP-100G-SR4 | 100G Base-SR4 Optical Transceiver, QSFP28, 100G, Multi-mode (850 nm, 0.1 km, MPO) |
QSFP-100G-PSM4 | 100G Base-PSM4 Optical Transceiver, QSFP28, 100G, Single-mode modul (1,310 nm, 0.5 km, MPO) |
BIDI-SFP optical transceivers | |
SFP-FE-LX-SM1310-BIDI | Optisk transceiver, eSFP, FE, BIDI single-mode module (TX1310/RX1550, 15 km, LC) |
SFP-FE-LX-SM1550-BIDI | Optisk transceiver, eSFP, FE, BIDI single-mode module (TX1550/RX1310, 15 km, LC) |
SFP-GE-LX-SM1310-BIDI | Optisk transceiver, eSFP, GE, BIDI single-mode module (TX1310/RX1490,10 km, LC) |
SFP-GE-LX-SM1490-BIDI | Optisk transceiver, eSFP, GE, BIDI single-mode module (TX1490/RX1310,10 km, LC) |
LE2MGSC40ED0 | Optisk transceiver, SFP, GE, BIDI single-mode module (TX1490/RX1310, 40 km, LC) |
LE2MGSC40DE0 | Optisk transceiver, SFP, GE, BIDI single-mode module (TX1310/RX1490, 40 km, LC) |
SFP-GE-ZBXD1 | Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1570/RX1490, 80 km, LC) |
SFP-GE-ZBXU1 | Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1490/RX1570, 80 km, LC) |
BIDI-SFP+ optical transceivers | |
SFP-10G-ER-SM1330-BIDI | Optical Transceiver, SFP+, 10G, BIDI Single-mode Module (TX1330/RX1270, 40 km, LC) |
SFP-10G-ER-SM1270-BIDI | Optical Transceiver, SFP+, 10G, BIDI Single-mode Module (TX1270/RX1330, 40 km, LC) |
SFP-10G-BXU1 | 10G Base, Bi-Directional (BIDI) optical transceiver, SFP, 10G, single-mode module (TX1270/RX1330, 10 km, LC) |
SFP-10G-BXD1 | 10G Base, BIDI optical transceiver, SFP, 10G, single-mode module (TX1330/RX1270, 10 km, LC) |
High-Speed Cable | |
SFP-10G-CU1M | SFP+,10G, High-Speed Direct-attach Cables, 1m, SFP + 20M, CC2P0.254B(S), SFP + 20M, used indoors |
SFP-10G-CU3M | SFP+, 10G, High-Speed Direct-attach Cables, 3m, SFP + 20M, CC2P0.254B(S), SFP + 20M, used indoors |
SFP-10G-CU5M | SFP, 10G, High-Speed Cable, 5m, SFP + 20M, CC2P0.254B(S), SFP + 20M, LSFRZH for indoors |
SFP-10G-AC10M | SFP+, 10G, Active High-Speed Cables, 10m, SFP + 20M, CC2P0.32B(S), SFP + 20M, used indoors |
QSFP-4SFP10G-CU1M | QSFP+, 4SFP + 10G, High-Speed Direct-attach Cables, 1m, QSFP + 38M, CC8P0.254B(S), 4 x SFP + 20M, used indoors |
QSFP-4SFP10G-CU3M | QSFP+, 4SFP + 10G, High-Speed Direct-attach Cables, 3m, QSFP + 38M, CC8P0.32B(S), 4 x SFP + 20M, used indoors |
QSFP-4SFP10G-CU5M | QSFP+, 4SFP + 10G, High-Speed Direct-attach Cables, 5m, QSFP + 38M, CC8P0.4B(S), 4 x SFP + 20M, used indoors |
QSFP-40G-CU1M | QSFP+, 40G, High-Speed Direct-attach Cables, 1m, QSFP + 38M, CC8P0.254B(S), QSFP + 38M, used indoors |
QSFP-40G-CU3M | QSFP+, 40G, High-Speed Direct-attach Cables, 3m, QSFP + 38M, CC8P0.32B(S), QSFP + 38M, used indoors |
QSFP-40G-CU5M | QSFP+, 40G, High-Speed Direct-attach Cables, 5m, QSFP + 38M, CC8P0.40B(S), QSFP + 38M, used indoors |
QSFP-100G-CU1M | High-Speed Cable, 100G QSFP28 Passive High-Speed Cable, 1m, QSFP28, CC8P0.254B(S), QSFP28, ETH 100 GbE |
QSFP-100G-CU3M | High-Speed Cable, 100G QSFP28 Passive High-Speed Cable, 3m, QSFP28, CC8P0.254B(S), QSFP28, ETH 100 GbE |
QSFP-100G-CU5M | High-Speed Cable, 100G QSFP28 Passive High-Speed Cable, 5m, QSFP28, CC8P0.4B(S), QSFP28, ETH 100 GbE |
Optisk fiber | |
SFP-10G-AOC3M | AOC Optical Transceiver, SFP+, 850 nm, 1G to 10G, 0.003 km |
SFP-10G-AOC10M | AOC Optical Transceiver, SFP+, 850 nm, 1G to 10G, 10m |
QSFP-H40G-AOC10M | Optisk transceiver, QSFP+, 40G, (850 nm, 10m, AOC) |
QSFP-4SFP10-AOC10M | Optisk transceiver, QSFP+, 40G, (850 nm, 10m, AOC) (connecting to four SFP+ optical transceivers) |
QSFP-100G-AOC10M | High-Speed Transceiver, QSFP28 to QSFP28 AOC, 850 nm, 100G, 0.01 km |
Power modules | |
PAC-2200WF | 2,200W AC-strömmodul |
PDC-2200WF | 2,200W DC-strömmodul |
W2PSA0800 | 800W AC Power Module (svart) |
programvara | |
ET1SBSM28000 | S12700 V200R008C00 software |
ET1SBSM2A000 | S12700 V200R010C00 software |
ET1SBSM2B010 | S12700 V200R011C10 software |
ET1SBSM2C000 | S12700 V200R012C00 software |
ET1SBSM2D000 | S12700 V200R013C00 Mainframe Software |
Licens | |
ET1SMPLS0000 | MPLS Function License |
ET1SNQA00000 | NQA Function License |
ET1SIPV60000 | IPV6 Function License |
ET1SSVFF0000 | SVF Function License (applicable only to the S12700 series) |
ET1SVXLAN000 | VXLAN enhanced function license(used in S12700 series) |
ET1SFIB128K0 | X-series LPU FIB Resource License-128K |
ET1SFIB512K0 | X-series LPU FIB Resource License-512K |
ET1SWL512AP0 | WLAN Access Controller AP Resource License-512AP (with the X-series LPU used) |
ET1SWL128AP0 | WLAN Access Controller AP Resource License-128AP (with the X-series LPU used) |
ET1SWL64AP00 | WLAN Access Controller AP Resource License-64AP (with the X-series LPU used) |
ET1SWL16AP00 | WLAN Access Controller AP Resource License-16AP (with the X-series LPU used) |
L-ACU2-128AP | ACU2 Wireless Access Controller AP Resource License (128 AP) |
L-ACU2-256AP | ACU2 Wireless Access Controller AP Resource License (256 AP) |
L-ACU2-384AP | ACU2 Wireless Access Controller AP Resource License (384 AP) |
L-ACU2-512AP | ACU2 Wireless Access Controller AP Resource License (512 AP) |
Documentation | |
ET1IV2RDC0E0 | S12700 Series Agile Switches V200R013C00 Product Documentation |
Huawei S12708 Switch Product Applications