Opis

H3C S6520X-30QC-HI is an Advanced Aggregation 10GE Switch with 24×1/10GE SFP+ ports, 2×QSFP+ ports (40GE, se lahko razdeli na štiri vrata 10GE.), 2× razširitvene reže, 2× reže za ventilatorski pladenj, in 2×reži za napajalni modul

H3C S6520X-30QC-HI Product Overview

To je vodilno visokozmogljivo in razširljivo dostopovno stikalo 10GE z modularnim dvojnim napajanjem, fiksne ali modularne povezave navzgor (10GE/40GE/100GE) in IRF za odpornost. The product offers high-density 10GE forwarding and can expand 10GE ports flexibly. It provides 48/24*10/1GE autosensing SFP+ ports, six QSFP28 ports or two QSFP28 or QSFP+ ports onboard with two expansion slots that support up to 11 kinds of modules range from GE to 10GE, 25GE, 40GE,100GE and Multigiga ports. Using a QSFP+ to SFP+ splitter cable, you can split a QSFP+ port into four line-rate 10GE SFP+ ports. Max 72*10GE supported on one single switch

H3C S6520X-30QC-HI Product Pictures

S6520X-30QC-HI price and specs

H3C S6520X-30QC-HI Product Specifications

Postavka S6520X-54HC-HI S6520X-54QC-HI S6520X-30HC-HI S6520X-30QC-HI S6520X-54HF-HI S6520X-30HF-HI
procesor Dual Core, 1.6GHz
Preklopna zmogljivost vrat 2160Gbps 1440Gbps 1680Gbps 960Gbps 2160Gbps 1680Gbps
Hitrost posredovanja paketov 1050poslanci 705poslanci 1050poslanci
Preklopna zmogljivost sistema 2.56Tb/s
Dimenzije (V × Š × G) 43.6 × 440 × 360 mm (1.72 × 17.32 × 14.17 v)
Utež ≤ 7.6 kg ≤ 7.2 kg ≤ 7.4 kg ≤ 7 kg ≤ 6.5 kg ≤ 6 kg
Flash/SDRAM 1GB/2 GB
Medpomnilnik paketov 12M
Konzolna vrata 1
Upravljanje Ethernet vrat 1
vrata USB 1
Vrata mikro USB 1
SFP+ 48 48 24 24 48 24
QSFP+ 2 2
QSFP28 2 2 6 6
Razširitvene reže 2 N/A
Združljivi vmesniški moduli 2-Port 10G SFP Plus Ethernet optični vmesniški modul N/A
8-Port 10G SFP+ z vmesniškim modulom MACSec
8-Port 1/2,5/5G BASE-T Ethernet bakreni vmesniški modul
8-Port 1/2,5/5/10G BASE-T Ethernet bakreni vmesniški modul
2-vrata 25GE SFP28 vmesniški modul
2-vrata 40GE QSFP+ vmesniški modul
8-vrata 25GE SFP28 vmesniški modul (za S6520X-54HC-HI)
2-vrata 100GE QSFP28 vmesniški modul (za S6520X-54HC-HI)
Razpon vhodne napetosti Ocenjeno: 100 VAC do 240 VAC @ 50 Hz/60 Hz Območje nazivne napetosti: 100 do 240 VAC @ 50/60 Hz
Maks.: 90 VAC do 264 VAC @ 47 Hz do 63 Hz Maksimalno območje napetosti: 90 do 264 VAC @ 47to 63 Hz
Območje nazivne napetosti: –48 do –60VDC
Maksimalno območje napetosti: –36 do –72 VDC
Reže za napajanje 2
Pladnji za ventilatorje 2 vroče zamenljive ventilatorske plošče, invertibilni pretok zraka 3 vroče zamenljive ventilatorske plošče, invertibilni pretok zraka
Poraba energije MIN: MIN: MIN: MIN: MIN: MIN:
Enojna klima: 44W; Enojna klima: 39W; Enojna klima: 38W; Enojna klima: 38W; Enojna klima: 36W Enojna klima:38W
Dvojna klimatska naprava: 49W Dvojna klimatska naprava: 44W Dvojna klimatska naprava: 43W Dvojna klimatska naprava: 43W Dvojna klimatska naprava: 44W Dvojna klimatska naprava:46W
MAKS: MAKS: MAKS: MAKS: MAKS: MAKS:
Enojna klima: 249W. Enojna klima: 231W; Enojna klima: 197W; Enojna klima: 179W; Enojna klima: 177W Enojna klima:143W
Dvojna klimatska naprava: 251W Dvojna klimatska naprava: 234W Dvojna klimatska naprava: 200W Dvojna klimatska naprava: 183W Dvojna klimatska naprava:176W Dvojna klimatska naprava:145W
Delovna temperatura 0ºC do 45ºC (32°F do 113 °F)
Od -60m do 5000m nadmorske višine: Od 0m, največja delovna temperatura se vsakič zniža za 0,33 ℃ 100 nadmorska višina se poveča za 100m.
Temperatura skladiščenja -40℃ do 70 ℃(-40℉ do 158 ℉)
Delovanje & skladiščna vlažnost 5% RH do 95% RH, brez kondenzacije
MTBF(leto) 60.8 60.2 63.4 62.8 60.8 63.4
MTTR(ura) 1 1 1 1 1 1

H3C S6520X-30QC-HI Product Features

  • The switch supports Telemetry technology, which can send the switch’s real-time resource information and alarm information to the O&M platform through the gRPC protocol. The platform can realize network quality backtracking, troubleshooting, risk early warning, architecture optimization and other functions to accurately guarantee user experience by analyzing real-time data
  • The switch supports AAA authentications (vključno z avtentikacijo RADIUS) in dinamično ali statično vezavo uporabniških identifikatorjev, kot je uporabniški račun, naslov IP, MAC naslov, VLAN, in številko vrat. Uporaba stikala v povezavi s H3C IMC, lahko upravljate in spremljate spletne uporabnike v realnem času ter takoj ukrepate v primeru nelegitimnega vedenja. The switch offers a large number of inbound and outbound ACLs and VLAN-based ACL assignment. To poenostavi konfiguracije in prihrani vire ACL.
  • The switch uses standard GE ports instead of specialized ports for IRF links between IRF member devices. To strankam omogoča, da po potrebi določijo pasovno širino med navzgornjo povezavo, navzdolnja povezava, in sistemske povezave IRF. Poleg tega, Tkanina S6520X-HI IRF se lahko razteza čez omarico, več stojal, ali več kampusov.

H3C S6520X-30QC-HI and More S6520X Models

H3C S6520X-30QC-HI: 24 × 1/10GE SFP+ vrata, 2 × vrata QSFP+ (40GE, se lahko razdeli na štiri vrata 10GE.), 2 × razširitvene reže, 2 × reže za ventilatorski pladenj, in 2 × reže za napajalni modul
H3C S6520X-54QC-HI: 48 × 1/10GE SFP+ vrata, 2 × vrata QSFP+ (40GE, se lahko razdeli na štiri vrata 10GE.), 2 × razširitvene reže, 2 × reže za ventilatorski pladenj, in 2 × reže za napajalni modul
H3C S6520X-30HC-HI: 24 × 1/10GE SFP+ vrata, 2 × vrata QSFP28(100GE, se lahko razdeli na štiri vrata 25GE), 2 × razširitvene reže, 2 × reže za ventilatorski pladenj, in 2 × reže za napajalni modul
H3C S6520X-54HC-HI: 48 × 1/10GE SFP+ vrata, 2 × vrata QSFP28(100GE, se lahko razdeli na štiri vrata 25GE), 2 × razširitvene reže, 2 × reže za ventilatorski pladenj, in 2 × reže za napajalni modul
H3C S6520X-30HF-HI: 24 × 1/10GE SFP+ vrata, 6 × vrata QSFP28, 3 × reže za ventilatorski pladenj, in 2 × reže za napajalni modul
H3C S6520X-54HF-HI: 48 × 1/10GE SFP+ vrata, 6 × vrata QSFP28, 3 × reže za ventilatorski pladenj, in 2 × reže za napajalni modul

H3C S6520X-30QC-HI Ordering Info

Product ID Opis izdelka
LS-6520X-30QC-HI-GL H3C S6520X-30QC-HI L3 Ethernet Switch(24SFP Plus+2QSFP Plus+2Slot),No Power
LS-6520X-54QC-HI-GL H3C S6520X-54QC-HI L3 Ethernet Switch(48SFP Plus+2QSFP Plus+2Slot),No Power
LS-6520X-30HC-HI-GL H3C S6520X-30HC-HI L3 Ethernet Switch(24SFP Plus+2QSFP28+2Slot),No Power
LS-6520X-54HC-HI-GL H3C S6520X-54HC-HI L3 Ethernet Switch(48SFP Plus+2QSFP28+2Slot),No Power
LS-6520X-30HF-HI H3C S6520X-30HF-HI L3 Ethernet Switch with 24 SFP Plus Ports and 6 QSFP28 Ports,Without Power Supplies
LS-6520X-54HF-HI H3C S6520X-54HF-HI L3 Ethernet Switch with 48 SFP Plus Ports and 6 QSFP28 Ports,Without Power Supplies
LSWM1FANSCE Ethernet Switch Fan Module(Power to Port Airflow)
LSWM1FANSCBE Ethernet Switch Fan Module(Port to Power Airflow)
LSPM1FANSA-SN H3C Fan Module (Fan Panel Side Intake Airflow)
LSPM1FANSB-SN H3C Fan Module (Fan Panel Side Exhaust Airflow)
PSR250-12A-GL 250W AC Power Supply Module
PSR250-12A1-GL 250W AC Power Supply Module
PSR450-12D 450W DC Power Supply Module
PSR180-12A-F 180W Asset-Manageable AC Power Supply Module (Power Panel Side Intake Airflow)
PSR180-12A-B 180W Asset-Manageable AC Power Supply Module (Power Panel Side Exhaust Airflow)
LSWM2QP2P 2-Port 40G QSFP Plus Interface Card
LSWM2SP2PB 2-Port 10G SFP Plus Ethernet optični vmesniški modul
LSWM2SP4PB 4-Port 10G SFP Plus Ethernet optični vmesniški modul
LSWM2MGT8P 8-Port 1/2,5/5G BASE-T Ethernet bakreni vmesniški modul
LSWM2XMGT8P 8-Port 1/2,5/5/10G BASE-T Ethernet bakreni vmesniški modul
LSWM2ZSP2P 2-Port 25G SFP28 Ethernet Optical Interface Module
LSWM4SP8PM 8-Port 10G SFP Plus with MACSec Interface Module
LSWM2ZSP8P 8-Port 25G SFP28 Interface Module
LSWM2ZQP2P 2-Port 100G QSFP28 Interface Module
LIS-WX-128-BE Enhanced Access Controller License,128 dostopne točke
LIS-WX-32-BE Enhanced Access Controller License,32 dostopne točke
LIS-WX-16-BE Enhanced Access Controller License,16 dostopne točke
LIS-WX-8-BE Enhanced Access Controller License,8 dostopne točke
LIS-WX-1-BE Enhanced Access Controller License,1 AP
SFP-GE-SX-MM850-A 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC)
SFP-GE-LX-SM1310-A 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC)
SFP-GE-LH40-SM1310 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC)
SFP-GE-LH40-SM1550 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC)
SFP-GE-LH80-SM1550 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC)
SFP-GE-LH100-SM1550 1000BASE-LH100 SFP Transceiver, Single Mode (1550nm, 100km, LC)
SFP-GE-LX-SM1310-BIDI 1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1310/RX1490, 10km, LC)
SFP-GE-LX-SM1490-BIDI 1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1490/RX1310, 10km, LC)
SFP-GE-T 1000BASE-T SFP
SFP-XG-LH40-SM1550 SFP+ modul(1550nm,40km,LC)
SFP-XG-LX-SM1310-E SFP+ modul(1310nm,10km,LC)
SFP-XG-SX-MM850-E SFP+ modul(850nm,300m,LC)
SFP-25G-SR-MM850 25G SFP28 Optical Transceiver Module (850nm,100m,SR,MM,LC)
QSFP-40G-LR4-WDM1300 40GBASE-LR4 QSFP+ Optical Transceiver Module
QSFP-40G-CSR4-MM850 QSFP+ 40GBASE Optical Transceiver Module (850nm,300m,CSR4,Support 40G to 4*10G)
QSFP-40G-SR4-MM850 QSFP+ 40GBASE Optical Transceiver Module (850nm,100m,SR4,Support 40G to 4*10G)
QSFP-100G-SR4-MM850 100G QSFP28 Optical Transceiver Module (850nm,100m OM4,SR4,MPO)
QSFP-100G-LR4-WDM1300 100G QSFP28 Optical Transceiver Module(1310nm,10km,LR4,WDM,LC)
QSFP-100G-LR4L-WDM1300 100G QSFP28 Optical Transceiver Module (1310nm,2km,LR4L,CWDM4,LC)
CAB-CON-1.8m Single Cable,Console Serial Port Cable,1.8m,D9F,28UL20276(4p)(P296U),MPH-8P8C
LSWM1STK SFP+ Cable 0.65m
LSWM2STK SFP+ Cable 1.2m
LSWM3STK SFP+ Cable 3m
SFP-25G-D-CAB-1M 25G SFP28 to 25G SFP28 1m Passive Cable
SFP-25G-D-CAB-3M 25G SFP28 to 25G SFP28 3m Passive Cable
SFP-25G-D-CAB-5M 25G SFP28 to 25G SFP28 5m Passive Cable
LSWM1QSTK0 40G QSFP+ Cable 1m
LSWM1QSTK1 40G QSFP+ Cable 3m
LSWM1QSTK2 40G QSFP+ Cable 5m
LSWM1QSTK3 40G QSFP+ to 4x10G SFP+ Cable 1m
LSWM1QSTK4 40G QSFP+ to 4x10G SFP+ Cable 3m
LSWM1QSTK5 40G QSFP+ to 4x10G SFP+ Cable 5m
QSFP-100G-D-CAB-1M 100G QSFP28 to 100G QSFP28 1m Passive Cable
QSFP-100G-D-CAB-3M 100G QSFP28 to 100G QSFP28 3m Passive Cable
QSFP-100G-D-CAB-5M 100G QSFP28 to 100G QSFP28 5m Passive Cable
QSFP-100G-4SFP-25G-CAB-1M 100G QSFP28 to 4x25G SFP28 1m Passive Cable
QSFP-100G-4SFP-25G-CAB-3M 100G QSFP28 to 4x25G SFP28 3m Passive Cable
QSFP-100G-4SFP-25G-CAB-5M 100G QSFP28 to 4x25G SFP28 5m Passive Cable
QSFP-100G-D-AOC-7M 100G QSFP28 to 100G QSFP28 7m Active Optical Cable
QSFP-100G-D-AOC-10M 100G QSFP28 to 100G QSFP28 10m Active Optical Cable
QSFP-100G-D-AOC-20M 100G QSFP28 to 100G QSFP28 20m Active Optical Cable
OP-MPO8-8LC-10-M Fiber Connector,MPO(8 jedro)/PC,8LC/PC(0.5m),Večmodni(OM3),3.0mm,10.0m
OP-MPO8-MPO8-10-M Fiber connector,MPO(8 jedro)/PC,MPO(8 jedro)/PC,Večmodni(OM3),3.0mm,10.0m
OP-MPO8-MPO8-50-M Fiber connector,MPO(8 jedro)/PC,MPO(8 jedro)/PC,Večmodni(OM3),3.0mm,50.0m
OP-MPO8-MPO8-100-M Fiber connector,MPO(8 jedro)/PC,MPO(8 jedro)/PC,Večmodni(OM3),3.0mm,100.0m
OP-MPO8-MPO8-200-M Fiber connector,MPO(8 jedro)/PC,MPO(8 jedro)/PC,Večmodni(OM3),3.0mm,200.0m

H3C S6520X-30QC-HI Product Applications

H3C S6520X-30QC-HI





    oprosti, priloga ni na voljo !