Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Jadro

SKU: Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Jadro Kategória: Tag:

Popis

Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Core is designed to protect fiber optic cable splicing and joints. They feature a seal that makes them both dust and weather resistant. They are used in underground applications and temperatures ranging from -40°C to 65°C, and widely applied in CATV, telecommunications and fiber optic networks

Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Základný prehľad

Vertical fiber optic closure looks like a dome, thus it is also called dome fiber optic splice closure or fiber dome closure. The dome shape makes it easy to be buried in many applications, though it also can be used above-ground as well.
Fiber optic closure, also known as fiber optic splicing closures, is a device used to provide space and protection for fiber optic cables spliced together. Optický uzáver bezpečne spája a ukladá optické vlákna buď vo vonkajšom závode alebo vo vnútorných budovách. It can provide protection for the fiber joint and the fiber cables since they have excellent mechanical strength and strong out shell, which ensures the joints are not damaged by the hostile environmen

Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Základné obrázky

Vertikálny typ krytu spoja optických vlákienFiber Optic Splice Enclosure Vertical Type price

Fiber Optic Splice Enclosure Vertical Type price and specsFiber Optic Splice Enclosure Vertical Typeycict

Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Základné špecifikácie

Položka fiber optic splice closure
Použite Dome splice closure for Fiber optic manufacture
Typ Dome splice closure

Číslo modelu

1 In 3 Vonku 24 Jadro
Inner box size 28.5*28*51cm
Outer box size 58.5*57.5*53cm
waterproof rating IP68
Standard and non-standard Štandardné
Materiál impact resistant PP
teplota -35℃~70℃
characterisation cold and heat resistant
Selling Units Single item
Single package size 47.5X23.5X20.5 cm
Single gross weight

5.000 kg

Farba

čierna

Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Základné vlastnosti

  • V a odolný voči chemikáliám
  • May be used for Cut, Uncut and Taut Sheath Applications
  • Prachu a vodeodolný dizajn
  • Ideálne pre letecké a podzemné aplikácie
  • Jednoduché nastavenie a inštalácia
  • Materiál: Polykarbonátový plast
  • šírka: 180mm
  • Výška: 540mm

Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Core Performance requirements

After the fiber connector is protected by the splice closure and should be protected from moisture, the attenuation of the fiber connector before protection should not be increased, and the following requirements should be met:

  • Optical performance

The remaining optical fibers in the optical cable splice closure are coiled in the optical fiber placement device, and there should be no obvious additional attenuation of the optical fiber splice splice closure during the installation and use of the optical fiber splice closure operation.

  • Sealing performance

After the optical cable splice closure is packaged according to the specified operating procedures, the inflation pressure in the optical cable splice splice closure is (100±5) kPa, and there should be no bubbles escaping after soaking it in a clean water container at room temperature for 15 minutes, or there should be no change in the barometer indication after stable observation for 24 hodiny.

  • Resealing performance

The optical cable splice closure is tested after repeating the package 3 times according to the specified operating procedure. The inflation pressure in the fiber optic cable splice splice box is l00kPa±5kPa, and there should be no bubbles escaping after soaking in a clean water container at room temperature for 15 minutes, or there should be no change in the barometer indication for 24 hodiny.

  • Mechanical properties

After the following tests, the box body and each part of the box of the optical cable splice splice box should not change, and if necessary, the light inspection or opening of the box should be done. The following tests should be filled with (60±5) kPa air pressure in the fiber optic cable splice closure and the air pressure should not change after the test; Stable observation in a clear water container immersed in room temperature No bubbles should escape or stable observation for 24 hodiny, the barometer index should be unchanged, and the shell and its components should be free of cracks, damage and obvious deformation

Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Core and More Items

Vertikálny typ krytu spoja optických vlákien 1 In 2 Vonku 12 Jadro
Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 12 Jadro
Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Jadro
Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 48 Jadro
Vertikálny typ krytu spoja optických vlákien 1 In 4 Vonku 72 Jadro
Vertikálny typ krytu spoja optických vlákien 1 In 4 Vonku 96 Jadro
Vertikálny typ krytu spoja optických vlákien 1 In 4 Vonku 144 Jadro

Vertikálny typ krytu spoja optických vlákien 1 In 3 Vonku 24 Základné aplikácie

Huawei AP8150DN topology huawei access point





    Prepáč, nie je k dispozícii žiadna príloha !