- Descriere
- Anchetă
- Atașament
Descriere
Huawei NE05E-SQ Router is the cloud era ENP Based Mid Services Router, which can be flexibly applied to IP / MPLS network edge access scenarios, to meet the diverse needs of users for future business development.
Huawei NE05E-SQ Router Product Overview
Huawei NE05E-SQ Router is designed with small size, lățime de bandă mare, and it supports for -40ºC to 65ºC working temperature range, potrivite pentru medii dificile. The product helps transportation, finanţa, putere, government, educaţie, enterprise to build agile networks.
An NE device is generally located at the intersection between an enterprise’s internal network and an external network. An NE05E or NE08E is the only entrance and exit of data flows between the internal and external networks. An NE05E or NE08E can bear multiple types of services, greatly reducing network construction investment and long-term operation and maintenance costs of an enterprise network.
Huawei NE05E-SQ Router Product Pictures
Huawei NE05E-SQ Router Product Specifications
Articol | NE05E-SR | NE05E-SQ | NE08E-S6E | NE08E-S9 |
Dimensiuni (Înălțime x L x A) | 43.6 mm x 250 mm x 180 mm (1.72 în. X 9.84 în. X 7.09 în.) | 44.45 mm x 442 mm x 220 mm (1.75 în. X 17.40 în. X 8.66 în.) | 88.90 mm x 442 mm x 220 mm (3.50 în. X 17.40 în. X 8.66 în.) | 155.58 mm x 442 mm x 220 mm (6.12 în. X 17.40 în. X 8.66 în.) |
Greutate (gol) | N / A | N / A | 3.5 kg | DC:7.9 kg |
AC:10.3 kg | ||||
Greutate (configurație completă) | 1.7kg | DC:4.7kg | 9.17kg | NEJ1CXPA DC:17.32kg |
AC:4.9kg | NEJ1CXPA AC:18.04kg | |||
Standard de instalare a dulapului | IMB(3U), ETSI(21-inch), IEC(19-inch) | R01S100 Outdoor Cabinet, ETSI(21-inch), IEC(19-inch) | R01S200 Outdoor Cabinet, ETSI(21-inch), IEC(19-inch) | R01S300A Outdoor Cabinet, ETSI(21-inch), IEC(19-inch) |
Consumul de energie tipic | AC:12.8W | 2 channel DC System:82.8w | 2 channel DC System, with 160G CXP Protection:111W | NEJ1CXPA DC System with CXP Protection:182w |
2 channel AC System:85.6w | 2 channel DC System, without 160G CXP Protection:57.45W | NEJ1CXPA AC System with CXP Protection:254w | ||
AC+DC system:84.2w | ||||
Disiparea tipică a căldurii | AC:41.5BTU/oră | 2 channel DC System:268.6BTU/oră | 2 channel DC System, with 160G CXP Protection:360.1BTU/oră | NEJ1CXPA DC:590.4BTU/oră |
2 channel AC System:277.7BTU/oră | 2 channel DC System, without 160G CXP Protection:184.4BTU/oră | NEJ1CXPA AC:824.0BTU/oră | ||
AC+DC system:273.1BTU/oră | ||||
Tensiunea de intrare DC | input voltage range: 19V to 30V or -38.4V to -72V | input voltage range: -38.4V la -72V | input voltage range: -38.4V la -72V | input voltage range: -38.4V la -72V |
input rated voltage: 24/-48V/-60V | input rated voltage: -48V/-60V | input rated voltage: -48V/-60V | input rated voltage: -48V/-60V | |
Tensiunea de intrare AC | input voltage range: 100 to 240V | input voltage range: 100 to 240V | input voltage range: N / A | input voltage range: 100 to 240V |
input rated voltage: 110V/220V | input rated voltage: 110V/220V | input rated voltage: N / A | input rated voltage: 110V/220V | |
MTBF | 40 ani | 40 ani | 40 ani | 40 ani |
MTTR | 2 ore | 2 ore | 2 ore | 2 ore |
Disponibilitate | 0.99999 | 0.99999 | 0.99999 | 0.99999 |
MPU-uri redundante | – | – | 1+1 | 1+1 |
Ventilatoare redundante | Natural heat dissipation, no fan | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 50°C. | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C. | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C. |
Alimentare redundantă | N / A | 1+1 | 1+1 | 1+1 |
Capacitate de comutare | 12 Gbit/s (Bidirecțional) | 272 Gbit/s (Bidirecțional) | NED3CXPA :320 Gbit/s@256 bytes (Bidirecțional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. | NEJ1CXPA :320 Gbit/s@256 bytes (Bidirecțional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. |
NED3CXPB :320 Gbit/s@256 bytes (Bidirecțional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. | ||||
Temperatura de Operare | Long-term: -40°C to 60°C | Long-term: DC:-40°C to 65°C AC:-20°C to 65°C | Long-term: DC:-40°C to 65°C(160G) | Long-term: -40°C to 65°C |
Short-term: N / A | Short-term: N / A | Short-term: N / A | Short-term: N / A | |
Observație: Restriction on the temperature variation rate: 30 °C/hour | Observație: Restriction on the temperature variation rate: 30 °C/hour | Observație: Restriction on the temperature variation rate: 30 °C/hour | Observație: Restriction on the temperature variation rate: 30 °C/hour | |
Temperatura de depozitare | -40°C până la 70°C | -40°C până la 70°C | -40°C până la 70°C | -40°C până la 70°C |
Relative operating humidity | Long term: 5% la 95% RH, necondens | Long term: 5% la 95% RH, necondens | Long term: 5% la 95% RH, necondens | Long term: 5% la 95% RH, necondens |
Short term: N / A | Short term: N / A | Short term: N / A | Short term: N / A | |
Relative storage humidity | 5% la 100% RH, necondens | 5% la 100% RH, necondens | 5% la 100% RH, necondens | 5% la 100% RH, necondens |
Altitudine de operare pe termen lung | ≤ 4000 metri. If the altitude is between 1800 meters and 4000 metri, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. | ≤ 4000 metri. If the altitude is between 1800 meters and 4000 metri, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. | ≤ 4000 metri. If the altitude is between 1800 meters and 4000 metri, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. | ≤ 4000 metri. If the altitude is between 1800 meters and 4000 metri, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. |
Altitudinea de depozitare | Lower than 5000 metri | Lower than 5000 metri | Lower than 5000 metri | Lower than 5000 metri |
Huawei NE05E-SQ Router Product Features
- GE/10GE interfaces
- interfețe E1
- CPOS interfaces
- Power voice interfaces
- IP FRR, LDP FRR, TE FRR, and VPN FRR
- TE-tunnel APS
- PW redundancy protection and PW APS
- Bit error-triggered protection switching
- NE08E: 1+1 hot backup for CXP boards (functioning as MPUs, SFU-uri, and clock boards at the same time)
- NE08E: non-stop routing (NSR)
Huawei NE05E-SQ and More Related Models
NE05E-S2
NE05E-SE
NE05E-SF
NE05E-SG
NE05E-SH
NE05E-DA
NE05E-SJ
NE05E-SK
NE05E-SL
NE05E-SM
NE05E-SN
NE05E-SQ
NE05E-SR
Huawei NE05E-SQ Product Applications
Îmi pare rău, nici un atașament disponibil !