- Descriere
- Anchetă
- Atașament
Descriere
ADSS Cable is all Dielectric Self-supporting Aerial Cable complying with Standard IEEE P 1222 as well as IEC 60794-1.
ADSS Cable Product Overview
All Dielectric Self Supporting optical cables, due to its unique structure, good insulation and high temperature resistance, as well as high tensile strength and many other advantages, provides fast and economical transmission channels for power communication systems. In general, ADSS fiber optic cables are cheaper than OPtical fiber composite ground wh (OPGW) in many applications, and it is easier to install. It is advisable to erect ADSS cables using power lines or nearby towers, and in some places ADSS cables are even necessary. The main uses of ADSS fiber optic cables are:
1) Using it as the introduction and exit optical cable of OPGW system relay station, based on its safety attributes, when introducing and exiting relay stations, it can well solve the problem of power isolation.
2) Use it as a transmission cable for optical fiber communication systems in high-voltage (110kV-220kV) power grid. In particular, many places have made it convenient to use when retrofitting old communication lines.
3) It is used for optical fiber communication system in 6kV~35kV~180kV distribution network.
ADSS Cable Product Pictures
ADSS Cable P肉duct Specifications
G.652 | G.655 | 50/125μm | 62.5/125μm | ||
Atenuare (+20℃) | @850nm | ≤3,0 dB/km | ≤3,0 dB/km | ||
@1300nm | ≤1,0 dB/km | ≤1,0 dB/km | |||
@1310nm | ≤0,36 dB/km | ≤0,40 dB/km | |||
@1550nm | ≤0,22 dB/km | ≤0,23 dB/km | |||
Lățimea de bandă (Clasa a) | @850nm | ≥500 MHz·km | ≥200 MHz·km | ||
@1300nm | ≥1000 MHz·km | ≥600 MHz·km | |||
Diafragma numerică | 0.200±0,015NA | 0.275±0,015NA | |||
Lungime de undă de tăiere a cablului | ≤1260nm | ≤1480nm |
ADSS Cable Product Features
- Can be installed without shutting off the power
- Large span lengths and the largest span is over 1000m
- Good performance of tensile strength and temperature
- The design life span is 30 ani
- Excellent AT performance, The maximum inductive at the operating point of AT sheath can reach 25kV
- Light weight and small diameter reducing the load caused by ice and wind and the load on towers and backprops
ADSS Cable and More Optical Cables
Cablu micro nemetalic unitube interior/exterior(JET)
Cablu nemetalic neblintat Unitube(GYFXY)
Două cabluri de fibră optică aeriană FRP (VIAȚA MEA)
Cablu neblintat cu tuburi libere (GYTA)
Cablu blindat ușor cu tuburi libere (GYTS)
Cablu blindat cu tuburi libere (GYTY53)
Cablu blindat cu tuburi libere (GYTA53)
Cablu non-blintat pentru membru de rezistență nemetalic (GYFTY)
Cablu non-blintat pentru membru de rezistență nemetalic(ÎMPREUNĂ)
Cablu blindat pentru membru de rezistență nemetalic (GYFTY53)
Cablu blindat pentru membru de rezistență nemetalic (GYFTA53)
Toate cablurile aeriene autoportante dielectrice (ADSS)
Toate cablurile aeriene autoportante dielectrice (ADSS)
ADSS Cable Product Applications
Îmi pare rău, nici un atașament disponibil !