Huawei S12708 Switch features 4.88/16.08 Tbit/s Switching Capacity 12.32/44.96 Tbit/s Packet Forwarding Rate 2 Slots MPU 4 Caça-níqueis SFU 6 Service Card Slots
Huawei S12708 Switch Product Overview
Huawei S12708 Switch is designed for next-generation campus networks, which uses a fully programmable architecture to meet fast-changing service needs. Huawei S12708 Switch allows new services to be flexibly and quickly provisioned in six months. Huawei S12708 Switch provides high-performance Layer 2/Layer3 switching services, supports millions of hardware entries, and can meet campus network evolution over the next 10 anos. Huawei S12708 Switch has built-in large-capacity WLAN AC functionalities, alcançando convergência com e sem fio e eliminando o gargalo de capacidade dos ACs.
Huawei S12708 Switch Product Pictures
Huawei S12708 Switch Product Specifications
Item | S12704 | S12708 | S12710 | S12712 |
Capacidade de comutação | 4.88Tbps/16,08*Tbps | 12.32Tbps/44,96*Tbps | 13.12Tbps/38,56*Tbps | 17.44Tbps/44,96*Tbps |
Taxa de encaminhamento de pacotes | 3, 120Mpps/4, 560*MPs | 6, 240Mpp/30, 240*MPs | 7, 440Mpps/11, 040*MPs | 9, 120Mpp/30, 240*MPs |
Slots MPU | 2 | 2 | 2 | 2 |
Slots SFU | 2 | 4 | 4 (2 integrado na MPU) | 4 |
Slots de cartão de serviço | 4 | 8 | 10 | 12 |
De slots | 2 | 4 | 4 | 5 |
Tamanho do buffer | 200ms armazena buffer em cada porta | |||
Projeto de redundância | MPUs, SFUs, suprimentos de energia, e módulos de ventilador | |||
CSS2 | 1+N backup de MPUs em um cluster | |||
Até 1.92 Largura de banda do cluster em Tbit/s, 4 latência de transmissão entre chassis μs | ||||
Dimensões (A x L x P em mm) | 441.7x442x489, 10você | 663.95x442x489, 15você | 663.95x442x489, 15você | 841.75x442x489, 19você |
Peso (chassi vazio) | 24.5kg | 42kg | 28.6kg | 64kg |
Tensão operacional | CC:–40V~–72V | |||
AC:90V~290V | ||||
Consumo máximo de energia de todo o equipamento | ≤2200W | ≤4400W | ≤4400W | ≤6600W |
Recursos do produto do switch Huawei S12708
OPS
Sistema de Programação Aberto (OPS) é um sistema programável aberto baseado na linguagem Python. Os administradores de TI podem programar o O&Funções M de uma mudança por meio de scripts Python para inovar funções rapidamente e implementar O inteligente&M.
Colaboração em segurança de big data
Os switches ágeis usam o NetStream para coletar dados da rede do campus e, em seguida, reportá-los ao Sistema de Inteligência de Segurança Cibernética da Huawei (CEI). O objetivo de fazer isso é detectar ameaças à segurança da rede, exibir a postura de segurança em toda a rede, e permitir resposta automática ou manual a ameaças à segurança. O CIS entrega as políticas de segurança ao Agile Controller. O Agile Controller então entrega essas políticas para switches ágeis que irão lidar com eventos de segurança adequadamente. Tudo isso garante a segurança da rede do campus.
Diagnóstico inteligente
Sistema de diagnóstico inteligente aberto (OIDS) integra as funções de monitoramento da integridade do dispositivo e diagnóstico de falhas – que normalmente são implantadas em um sistema de gerenciamento de rede (SMN) – no software do switch para implementar diagnóstico inteligente em um único switch. Depois que o OIDS for implantado em um switch, o switch coleta e registra periodicamente as informações de funcionamento e determina automaticamente se ocorre uma falha. Se ocorrer uma falha, a chave localiza automaticamente a falha ou ajuda a localizar a falha. Todos esses méritos aumentam a eficiência de localização de falhas de O&M equipe enquanto melhora a capacidade de manutenção do dispositivo.
Informações sobre pedidos de produtos do switch Huawei S12708
LE2BN66ED000 | Rack de montagem N66E DC (oito saídas 60A, máximo de 2.200 W por saída, 600 x 600 x 2,200 milímetros) |
LE2BN66EA000 | Rack de montagem CA N66E (quatro saídas 16A, máximo de 2.500 W por saída, 600 x 600 x 2,200 milímetros) |
ET1BS12704S0 | Chassi de montagem S12704 |
ET1BS12708S0 | Chassi de montagem S12708 |
ET1BS12710S0 | Chassi de montagem S12710 |
ET1BS12712S0 | Chassi de montagem S12712 |
ET1MFBX00000 | Ampla Tensão 129 Caixa de ventilador |
EH1M00FBX000 | Ampla Tensão 74 Caixa de ventilador |
Unidade de monitoramento | |
EH1D200CMU00 | Unidade de monitoramento centralizado |
Unidade de processamento principal | |
ET1D2MPUA000 | Unidade de controle principal S12700 A, relógio opcional |
ET1D2MPUBC00 | Unidade de controle principal S12710 B, relógio opcional |
ET1D2MPUBC01 | S12710, Unidade Principal de Processamento B (suporta inicialização segura) |
ET1D2MPUDC00 | S12704/S12708/S12712, unidade de processamento principal D |
Trocar unidade de tecido | |
ET1D2SFUA000 | Unidade A da malha de comutação S12700 |
ET1D2SFUB000 | Unidade de malha de comutação S12700 B |
ET1D2SFUC000 | Unidade de malha de comutação S12700 C |
ET1D2SFUD000 | Unidade de malha de comutação S12700 D |
100Placas de interface elétrica Ethernet M/1.000M | |
ET1D2G48TEA0 | 48-porta 10/100/1,000 Placa de interface BASE-T (EA, RJ45) |
ET1D2G48TEC0 | 48-porta 10/100/1,000 Placa de interface BASE-T (CE, RJ45) |
ET1D2G48TX1E | 48-porta 10/100/1,000 Placa de interface BASE-T (X1E, RJ45) |
ET1D2G48TX5S | 48-placa de interface porta 100/1000BASE-T (X5S, RJ45) |
ET1D2G48TX5E | 48-placa de interface porta 100/1000BASE-T (X5E, RJ45) |
ET1D2G48TX5H | 48-placa de interface porta 100/1000BASE-T (X5H, RJ45) |
100Placas de interface óptica Ethernet M/1.000M | |
ET1D2G24SEC0 | 24-porta 100/1,000 Placa de interface BASE-X (CE, SFP) |
ET1D2G24SX5E | 24-placa de interface porta 100/1000BASE-X (X5E, SFP) |
ET1D2G48SEA0 | 48-porta 100/1,000 Placa de interface BASE-X (EA, SFP) |
ET1D2G48SEC0 | 48-porta 100/1,000 Placa de interface BASE-X (CE, SFP) |
ET1D2G48SX1E | 48-porta 100/1,000 Placa de interface BASE-X (X1E, SFP) |
ET1D2G48SX5S | 48-placa de interface porta 100/1000BASE-X (X5S, SFP) |
ET1D2G48SX5E | 48-placa de interface porta 100/1000BASE-X (X5E, SFP) |
ET1D2G48SX5H | 48-placa de interface porta 100/1000BASE-X (X5H, SFP) |
100Placas de interface elétrica e óptica Ethernet M/1.000M | |
ET1D2T36SEA0 | 36-porta 10/100/1000 BASE-T e 12 portas 100/1000 Placa de interface BASE-X (EA, RJ45/SFP) |
10 Placas de interface óptica GE | |
ET1D2S04SX1E | 4-porta 10G BASE-X e 24 portas 100/1000 BASE-X e 8 portas 10/100/1000 Placa de interface combinada BASE-T (X1E, RJ45/SFP/SFP+) |
ET1D2S04SX5E | 4-porta 10GE SFP+ e placa de interface GE SFP de 44 portas (X5E, SFP+) |
ET1D2S08SX1E | 8-porta 10G BASE-X e 8 portas 100/1000 BASE-X e 8 portas 10/100/1000 Placa de interface combinada BASE-T (X1E, RJ45/SFP/SFP+) |
ET1D2X08SX5E | 8-porta 10GE placa de interface SFP+ (X5E, SFP+) |
ET1D2X08SX5H | 8-porta 10GE placa de interface SFP+ (X5H, SFP+) |
ET1D2X16SSC2 | 16-Placa de interface da porta 10GBASE-X(SC, SFP+) |
ET1D2X32SSC0 | 32-Placa de interface da porta 10GBASE-X(SC, SFP+) |
ET1D2X48SEC0 | 48-porta 10G placa de interface BASE-X (CE, SFP+) |
ET1D2X32SX2H | 32-Placa de interface porta 10GE SFP+(X2H, SFP+) |
ET1D2X32SX2S | 32-Placa de interface porta 10GE SFP+(X2S, SFP+) |
ET1D2X32SX2E | 32-Placa de interface porta 10GE SFP+(X2E, SFP+) |
ET1D2S24SX2S | 24-Interface de porta 10GE SFP+ e placa de interface GE SFP de 8 portas(X2S, SFP+) |
ET1D2S24SX2E | 24-Interface de porta 10GE SFP+ e placa de interface GE SFP de 8 portas(X2E, SFP+) |
ET1D2S16SX2S | 16-Interface de porta 10GE SFP+ e placa de interface GE SFP de 16 portas(X2S, SFP+) |
ET1D2S16SX2E | 16-Interface de porta 10GE SFP+ e placa de interface GE SFP de 16 portas(X2E, SFP+) |
ET1D2X48SX2S | 48-Placa de interface porta 10GE SFP+(X2S, SFP+) |
40 Placas de interface óptica GE | |
ET1D2L02QSC0 | 2-porta 40G placa de interface BASE-X (SC, QSFP+) |
ET1D2L08QSC0 | 8-porta 40G placa de interface BASE-X (SC, QSFP+) |
EH1D2L08QX2E | 8-Porta 40 Placa de interface GE QSFP+ (X2E, QSFP+) |
ET1D2L16QX2H | 16-Porta 40 Placa de interface GE QSFP+ (X2H, QSFP+) |
100 Placas de interface óptica GE | |
ET1D2C02FEE0 | 2-Placa de interface porta 100G BASE-X(EE,PCP) |
ET1D2C04HX2H | 4-Porta 100 Placa de interface GE QSFP28 (X2H, QSFP28) |
ET1D2C04HX2S | 4-Porta 100 Placa de interface GE QSFP28 (X2S, QSFP28) |
ET1D2C04HX2E | 4-Porta 100 Placa de interface GE QSFP28 (X2E, QSFP28) |
ET1D2C08HX2H | 8-Porta 100 Placa de interface GE QSFP28 (X2H, QSFP28) |
ET1D2H02QX2S | 2-Porta 100 Interface GE QSFP28 e 2 portas 40 Placa de interface GE QSFP+ (X2S, QSFP28) |
ET1D2H02QX2E | 2-Porta 100 Interface GE QSFP28 e 2 portas 40 Placa de interface GE QSFP+ (X2E, QSFP28) |
Subcartões de serviço | |
EH1D2VS08000 | 8-unidade de serviço do sistema de comutação de cluster de porta 10G (SFP+) |
ET1D2VQ06000 | 6-Porta 40 Unidade de serviço do sistema de comutação de cluster GE (QSFP+) |
LE0D00CKMA00 | Placa de pitada de relógio-1588 |
Cartões de processamento de serviço | |
ET1D2FW00S00 | Módulo NGFW A, com software de plataforma de segurança geral HW |
ET1D2FW00S01 | Módulo NGFW B, com software de plataforma de segurança geral HW |
ET1D2FW00S02 | Módulo NGFW C, com software de plataforma de segurança geral HW |
ET1D2IPS0S00 | Módulo IPS A, com software de plataforma de segurança geral HW |
ACU2 | Unidade controladora de acesso WLAN ACU2 (128 Recurso de controle AP incluído) |
Transceptores ópticos | |
Transceptor óptico FE-SFP | |
SFP-FE-SX-MM1310 | Transceptor óptico, SFP, 100M/155M, Módulo multimodo (1,310 nm, 2 quilômetros, LC) |
eSFP-FE-LX-SM1310 | Transceptor óptico, eSFP, 100M/155M, Módulo monomodo (1,310 nm, 15 quilômetros, LC) |
S-SFP-FE-LH40-SM1310 | Transceptor óptico, eSFP, FE, módulo monomodo (1,310 nm, 40 quilômetros, LC) |
S-SFP-FE-LH80-SM1550 | Transceptor óptico, eSFP, FE, módulo monomodo (1,550 nm, 80 quilômetros, LC) |
Transceptor óptico GE-SFP | |
SFP-1000BaseT | Transceptor de cobre, SFP, GE, módulo de interface elétrica (100eu, RJ45) |
eSFP-GE-SX-MM850 | Transceptor óptico, eSFP, GE, módulo multimodo (850 nm, 0.5 quilômetros, LC) |
SFP-GE-LX-SM1310 | Transceptor óptico, SFP, GE, módulo monomodo (1,310 nm, 10 quilômetros, LC) |
S-SFP-GE-LH40-SM1310 | Transceptor óptico, eSFP, GE, módulo monomodo (1,310 nm, 40 quilômetros, LC) |
S-SFP-GE-LH40-SM1550 | Transceptor óptico, eSFP, GE, módulo monomodo (1,550 nm, 40 quilômetros, LC) |
S-SFP-GE-LH80-SM1550 | Transceptor óptico, eSFP, GE, módulo monomodo (1,550 nm, 80 quilômetros, LC) |
eSFP-GE-ZX100-SM1550 | Transceptor óptico, eSFP, GE, módulo monomodo (1,550 nm, 100 quilômetros, LC) |
10 Transceptor óptico GE-XFP | |
XFP-SX-MM850 | Transceptor óptico, XFP, 10G, módulo multimodo (850 nm, 0.3 quilômetros, LC) |
XFP-STM64-LX-SM1310 | Transceptor óptico, XFP, 10G, módulo monomodo (1,310 nm, 10 quilômetros, LC) |
XFP-STM64-LH40-SM1550 | Transceptor óptico, XFP, 10G, módulo monomodo (1,550 nm, 40 quilômetros, LC) |
XFP-STM64-SM1550-80 km | Transceptor óptico, XFP, 10G, módulo monomodo (1,550 nm, 80 quilômetros, LC) |
10 Transceptor óptico GE-SFP+ | |
OMXD30000 | Transceptor óptico, SFP+, 10G, módulo multimodo (850 nm, 0.3 quilômetros, LC) |
OSX010000 | Transceptor óptico, SFP+, 10G, módulo monomodo (1,310 nm, 10 quilômetros, LC) |
OSX040N01 | Transceptor óptico, SFP+, 10G, módulo monomodo (1,550 nm, 40 quilômetros, LC) |
OSXD22N00 | Transceptor óptico, SFP+, 10G, módulo monomodo (1,310 nm, 0.22quilômetros, LC, LRM) |
SFP-10G-USR | Transceptor óptico, SFP+, 10G, módulo multimodo (850 nm, 0.1 quilômetros, LC) |
SFP-10G-ZR | Transceptor óptico, SFP+, 10G, módulo monomodo (1,550 nm, 80 quilômetros, LC) |
SFP-10G-ZCW1571 | Transceptor óptico, SFP+, 10G, módulo monomodo (CWDM, 1,571 nm, 70 quilômetros, LC) |
SFP-10G-ZCW1591 | Transceptor óptico, SFP+, 10G, módulo monomodo (CWDM, 1,591 nm, 70 quilômetros, LC) |
SFP-10G-ZCW1611 | Transceptor óptico, SFP+, 10G, módulo monomodo (CWDM, 1,611 nm, 70 quilômetros, LC) |
SFP-10G-iLR | Transceptor óptico, SFP+, 10G, módulo monomodo (DWDM, 1560.61–1529,16nm, 60quilômetros, LC) |
SFP-10G-ZDWT-L | Transceptor Óptico, SFP+, 9.8G, Módulo monomodo (1,310 nm, 1.4 quilômetros, LC) |
40 Transceptores ópticos GE | |
QSFP-40G-iSR4 | 40Transceptor óptico G Base-iSR4, QSFP, 40G, módulo multimodo (850 nm, 0.15 quilômetros, MPO) (conectando-se a quatro transceptores ópticos SFP+) |
QSFP-40G-LX4 | 40Transceptor óptico G Base-LX4, QSFP+, 40 GE, Modo único (1,310 nm, 2 quilômetros, LC), Multimodo (1,310 nm, 0.15 quilômetros, LC) |
QSFP-40G-iSM4 | 40Transceptor óptico G Base-iSM4, QSFP+, 40G, Módulo monomodo (1,310 nm, 1.4 quilômetros, MPO) (conectando-se a quatro transceptores ópticos SFP+) |
QSFP-40G-eSM4 | 40Transceptor óptico G Base-eSM4, QSFP+, 40G, Módulo monomodo (,1310 nm, 10 quilômetros, MPO) (conectando-se a quatro transceptores ópticos SFP+) |
QSFP-40G-LR4 | 40Transceptor óptico G Base-LR4, QSFP+, 40G, módulo monomodo (1,310 nm, 10 quilômetros, LC) |
QSFP-40G-eSR4 | 40Transceptor óptico G Base-eSR4, QSFP+, 40G, módulo multimodo (850 nm, 0.3 quilômetros, MPO) (conectando-se a quatro transceptores ópticos SFP+) |
CFP-40G-SR4 | Transceptor de alta velocidade, PCP, 40G, Módulo multimodo (850 nm, 4 x 10G, 0.1 quilômetros, MPO) |
CFP-40G-LR4 | Transceptor de alta velocidade, PCP, 40G, Módulo monomodo (1,310 banda nm, 41.25G, 10 quilômetros, LC direto) |
CFP-40G-ER4 | Transceptor de alta velocidade, PCP, 40G, Módulo monomodo (1,310 banda nm, 41.25G, 40 quilômetros, LC direto) |
CFP-40G-ZR4 | Transceptor de alta velocidade, PCP,40G, Módulo monomodo (1,550 banda nm, 41.25G, 80 quilômetros, LC direto) |
QSFP-40G-ER4 | 40Transceptor óptico G Base-ER4, QSFP+, 40G, Módulo monomodo (1,310 nm, 40 quilômetros, LC) |
100 Transceptores ópticos GE | |
CFP-100G-SR10 | Transceptor de alta velocidade, PCP, 100G, Módulo multimodo (850 nm, 10 x 10G, 0.1 quilômetros, MPO) (pode se conectar a 10 Portas SFP+ ou 2 Portas QSFP+) |
CFP-100G-LR4 | Transceptor de alta velocidade, PCP, 100G, Módulo monomodo (1,310 banda nm, 4 x 25G, 10 quilômetros, LC direto) |
CFP-100G-ER4 | Transceptor de alta velocidade, PCP, 100G, Módulo monomodo (1,310 banda nm, 4 x 25G, 40 quilômetros, LC direto) |
CFP-100GE-ZR4 | 100Base G,Módulo PCP, 100G, Módulo monomodo (1,310 banda nm, 4 x 25G, 80 quilômetros, LC direto) |
QSFP-100G-CLR4 | Transceptor de alta velocidade, QSFP28, 1,310 nm, 4 xBase 25G, -6.5 dBm, 2.5 dBm, -10.7 dBm, LC/PC, 2 quilômetros |
QSFP-100G-CWDM4 | Transceptor de alta velocidade, QSFP28, 1,310 nm, 4 xBase 25G, -6.5 dBm, 2.5 dBm, -9.8 dBm, LC/PC, 2 quilômetros |
QSFP-100G-ER4-Lite | 100Transceptor óptico G Base-ER4-Lite, QSFP28, 100G, Módulo monomodo (1,310 nm, 30 quilômetros (FEC DESLIGADO), 40 quilômetros (FEC LIGADO), LC) |
QSFP-100G-LR4 | 100Transceptor óptico G Base-LR4, QSFP28, 100G, Módulo monomodo (1,310 nm, 10 quilômetros, LC) |
QSFP-100G-SR4 | 100Transceptor óptico G Base-SR4, QSFP28, 100G, Multimodo (850 nm, 0.1 quilômetros, MPO) |
QSFP-100G-PSM4 | 100Transceptor óptico G Base-PSM4, QSFP28, 100G, Módulo monomodo (1,310 nm, 0.5 quilômetros, MPO) |
Transceptores ópticos BIDI-SFP | |
SFP-FE-LX-SM1310-BIDI | Transceptor óptico, eSFP, FE, Módulo BIDI monomodo (TX1310/RX1550, 15 quilômetros, LC) |
SFP-FE-LX-SM1550-BIDI | Transceptor óptico, eSFP, FE, Módulo BIDI monomodo (TX1550/RX1310, 15 quilômetros, LC) |
SFP-GE-LX-SM1310-BIDI | Transceptor óptico, eSFP, GE, Módulo BIDI monomodo (TX1310/RX1490,10km, LC) |
SFP-GE-LX-SM1490-BIDI | Transceptor óptico, eSFP, GE, Módulo BIDI monomodo (TX1490/RX1310,10 km, LC) |
LE2MGSC40ED0 | Transceptor óptico, SFP, GE, Módulo BIDI monomodo (TX1490/RX1310, 40 quilômetros, LC) |
LE2MGSC40DE0 | Transceptor óptico, SFP, GE, Módulo BIDI monomodo (TX1310/RX1490, 40 quilômetros, LC) |
SFP-GE-ZBXD1 | Transceptor Óptico, eSFP, GE, Módulo BIDI de modo único (TX1570/RX1490, 80 quilômetros, LC) |
SFP-GE-ZBXU1 | Transceptor Óptico, eSFP, GE, Módulo BIDI de modo único (TX1490/RX1570, 80 quilômetros, LC) |
Transceptores ópticos BIDI-SFP+ | |
SFP-10G-ER-SM1330-BIDI | Transceptor Óptico, SFP+, 10G, Módulo BIDI de modo único (TX1330/RX1270, 40 quilômetros, LC) |
SFP-10G-ER-SM1270-BIDI | Transceptor Óptico, SFP+, 10G, Módulo BIDI de modo único (TX1270/RX1330, 40 quilômetros, LC) |
SFP-10G-BXU1 | 10Base G, Bidirecional (BIDI) transceptor óptico, SFP, 10G, módulo monomodo (TX1270/RX1330, 10 quilômetros, LC) |
SFP-10G-BXD1 | 10Base G, Transceptor óptico BIDI, SFP, 10G, módulo monomodo (TX1330/RX1270, 10 quilômetros, LC) |
Cabo de alta velocidade | |
SFP-10G-CU1M | SFP+,10G, Cabos de conexão direta de alta velocidade, 1eu, SFP + 20M, CC2P0.254B(S), SFP + 20M, usado dentro de casa |
SFP-10G-CU3M | SFP+, 10G, Cabos de conexão direta de alta velocidade, 3eu, SFP + 20M, CC2P0.254B(S), SFP + 20M, usado dentro de casa |
SFP-10G-CU5M | SFP, 10G, Cabo de alta velocidade, 5eu, SFP + 20M, CC2P0.254B(S), SFP + 20M, LSFRZH para ambientes internos |
SFP-10G-AC10M | SFP+, 10G, Cabos ativos de alta velocidade, 10eu, SFP + 20M, CC2P0.32B(S), SFP + 20M, usado dentro de casa |
QSFP-4SFP10G-CU1M | QSFP+, 4SFP + 10G, Cabos de conexão direta de alta velocidade, 1eu, QSFP + 38M, CC8P0.254B(S), 4 xSFP + 20M, usado dentro de casa |
QSFP-4SFP10G-CU3M | QSFP+, 4SFP + 10G, Cabos de conexão direta de alta velocidade, 3eu, QSFP + 38M, CC8P0.32B(S), 4 xSFP + 20M, usado dentro de casa |
QSFP-4SFP10G-CU5M | QSFP+, 4SFP + 10G, Cabos de conexão direta de alta velocidade, 5eu, QSFP + 38M, CC8P0.4B(S), 4 xSFP + 20M, usado dentro de casa |
QSFP-40G-CU1M | QSFP+, 40G, Cabos de conexão direta de alta velocidade, 1eu, QSFP + 38M, CC8P0.254B(S), QSFP + 38M, usado dentro de casa |
QSFP-40G-CU3M | QSFP+, 40G, Cabos de conexão direta de alta velocidade, 3eu, QSFP + 38M, CC8P0.32B(S), QSFP + 38M, usado dentro de casa |
QSFP-40G-CU5M | QSFP+, 40G, Cabos de conexão direta de alta velocidade, 5eu, QSFP + 38M, CC8P0.40B(S), QSFP + 38M, usado dentro de casa |
QSFP-100G-CU1M | Cabo de alta velocidade, 100Cabo passivo de alta velocidade G QSFP28, 1eu, QSFP28, CC8P0.254B(S), QSFP28, ETH 100 Carregar |
QSFP-100G-CU3M | Cabo de alta velocidade, 100Cabo passivo de alta velocidade G QSFP28, 3eu, QSFP28, CC8P0.254B(S), QSFP28, ETH 100 Carregar |
QSFP-100G-CU5M | Cabo de alta velocidade, 100Cabo passivo de alta velocidade G QSFP28, 5eu, QSFP28, CC8P0.4B(S), QSFP28, ETH 100 Carregar |
Fibra ótica | |
SFP-10G-AOC3M | Transceptor Óptico AOC, SFP+, 850 nm, 1G a 10G, 0.003 quilômetros |
SFP-10G-AOC10M | Transceptor Óptico AOC, SFP+, 850 nm, 1G a 10G, 10eu |
QSFP-H40G-AOC10M | Transceptor óptico, QSFP+, 40G, (850 nm, 10eu, COA) |
QSFP-4SFP10-AOC10M | Transceptor óptico, QSFP+, 40G, (850 nm, 10eu, COA) (conectando-se a quatro transceptores ópticos SFP+) |
QSFP-100G-AOC10M | Transceptor de alta velocidade, QSFP28 a QSFP28 AOC, 850 nm, 100G, 0.01 quilômetros |
Módulos de potência | |
PAC-2200WF | 2,200Módulo de alimentação CA W |
PDC-2200WF | 2,200Módulo de alimentação DC W |
W2PSA0800 | 800Módulo de alimentação CA W (preto) |
Programas | |
ET1SBSM28000 | Software S12700 V200R008C00 |
ET1SBSM2A000 | Software S12700 V200R010C00 |
ET1SBSM2B010 | Software S12700 V200R011C10 |
ET1SBSM2C000 | Software S12700 V200R012C00 |
ET1SBSM2D000 | Software de mainframe S12700 V200R013C00 |
Licença | |
ET1SMPLS0000 | Licença de Função MPLS |
ET1SNQA00000 | Licença de Função NQA |
ET1SIPV60000 | Licença de Função IPV6 |
ET1SSVFF0000 | Licença de função SVF (aplicável apenas à série S12700) |
ET1SVXLAN000 | Licença de função aprimorada VXLAN(usado na série S12700) |
ET1SFIB128K0 | Licença de recurso LPU FIB da série X-128K |
ET1SFIB512K0 | Licença de recurso LPU FIB série X-512K |
ET1SWL512AP0 | Licença de recurso AP do controlador de acesso WLAN-512AP (com a LPU da série X usada) |
ET1SWL128AP0 | Licença de recurso AP do controlador de acesso WLAN-128AP (com a LPU da série X usada) |
ET1SWL64AP00 | Licença de recurso AP do controlador de acesso WLAN-64AP (com a LPU da série X usada) |
ET1SWL16AP00 | Licença de recurso AP do controlador de acesso WLAN-16AP (com a LPU da série X usada) |
L-ACU2-128AP | Licença de recurso AP do controlador de acesso sem fio ACU2 (128 PA) |
L-ACU2-256AP | Licença de recurso AP do controlador de acesso sem fio ACU2 (256 PA) |
L-ACU2-384AP | Licença de recurso AP do controlador de acesso sem fio ACU2 (384 PA) |
L-ACU2-512AP | Licença de recurso AP do controlador de acesso sem fio ACU2 (512 PA) |
Documentação | |
ET1IV2RDC0E0 | Documentação do produto dos switches ágeis série S12700 V200R013C00 |
Aplicações do produto do switch Huawei S12708