Description
Huawei NE05E-SQ Router is the cloud era ENP Based Mid Services Router, which can be flexibly applied to IP / MPLS network edge access scenarios, to meet the diverse needs of users for future business development.
Huawei NE05E-SQ Router Product Overview
Huawei NE05E-SQ Router is designed with small size, big bandwidth, and it supports for -40ºC to 65ºC working temperature range, suitable for difficult environments. The product helps transportation, finance, power, government, education, enterprise to build agile networks.
An NE device is generally located at the intersection between an enterprise’s internal network and an external network. An NE05E or NE08E is the only entrance and exit of data flows between the internal and external networks. An NE05E or NE08E can bear multiple types of services, greatly reducing network construction investment and long-term operation and maintenance costs of an enterprise network.
Huawei NE05E-SQ Router Product Pictures
Huawei NE05E-SQ Router Product Specifications
Item | NE05E-SR | NE05E-SQ | NE08E-S6E | NE08E-S9 |
Dimensions (H x W x D) | 43.6 mm x 250 mm x 180 mm (1.72 in. x 9.84 in. x 7.09 in.) | 44.45 mm x 442 mm x 220 mm (1.75 in. x 17.40 in. x 8.66 in.) | 88.90 mm x 442 mm x 220 mm (3.50 in. x 17.40 in. x 8.66 in.) | 155.58 mm x 442 mm x 220 mm (6.12 in. x 17.40 in. x 8.66 in.) |
Weight (empty) | N/A | N/A | 3.5 kg | DC:7.9 kg |
AC:10.3 kg | ||||
Weight (full configuration) | 1.7kg | DC:4.7kg | 9.17kg | NEJ1CXPA DC:17.32kg |
AC:4.9kg | NEJ1CXPA AC:18.04kg | |||
Cabinet installation standard | IMB(3U), ETSI(21-inch), IEC(19-inch) | R01S100 Outdoor Cabinet, ETSI(21-inch), IEC(19-inch) | R01S200 Outdoor Cabinet, ETSI(21-inch), IEC(19-inch) | R01S300A Outdoor Cabinet, ETSI(21-inch), IEC(19-inch) |
Typical power consumption | AC:12.8W | 2 channel DC System:82.8w | 2 channel DC System, with 160G CXP Protection:111W | NEJ1CXPA DC System with CXP Protection:182w |
2 channel AC System:85.6w | 2 channel DC System, without 160G CXP Protection:57.45W | NEJ1CXPA AC System with CXP Protection:254w | ||
AC+DC system:84.2w | ||||
Typical heat dissipation | AC:41.5BTU/hour | 2 channel DC System:268.6BTU/hour | 2 channel DC System, with 160G CXP Protection:360.1BTU/hour | NEJ1CXPA DC:590.4BTU/hour |
2 channel AC System:277.7BTU/hour | 2 channel DC System, without 160G CXP Protection:184.4BTU/hour | NEJ1CXPA AC:824.0BTU/hour | ||
AC+DC system:273.1BTU/hour | ||||
DC input voltage | input voltage range: 19V to 30V or -38.4V to -72V | input voltage range: -38.4V to -72V | input voltage range: -38.4V to -72V | input voltage range: -38.4V to -72V |
input rated voltage: 24/-48V/-60V | input rated voltage: -48V/-60V | input rated voltage: -48V/-60V | input rated voltage: -48V/-60V | |
AC input voltage | input voltage range: 100 to 240V | input voltage range: 100 to 240V | input voltage range: N/A | input voltage range: 100 to 240V |
input rated voltage: 110V/220V | input rated voltage: 110V/220V | input rated voltage: N/A | input rated voltage: 110V/220V | |
MTBF | 40 years | 40 years | 40 years | 40 years |
MTTR | 2 hours | 2 hours | 2 hours | 2 hours |
Availability | 0.99999 | 0.99999 | 0.99999 | 0.99999 |
Redundant MPUs | – | – | 1+1 | 1+1 |
Redundant fans | Natural heat dissipation, no fan | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 50°C. | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C. | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C. |
Redundant power supply | N/A | 1+1 | 1+1 | 1+1 |
Switching capacity | 12 Gbit/s (Bidirectional) | 272 Gbit/s (Bidirectional) | NED3CXPA :320 Gbit/s@256 bytes (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. | NEJ1CXPA :320 Gbit/s@256 bytes (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. |
NED3CXPB :320 Gbit/s@256 bytes (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. | ||||
Operating temperature | Long-term: -40°C to 60°C | Long-term: DC:-40°C to 65°C AC:-20°C to 65°C | Long-term: DC:-40°C to 65°C(160G) | Long-term: -40°C to 65°C |
Short-term: N/A | Short-term: N/A | Short-term: N/A | Short-term: N/A | |
Remark: Restriction on the temperature variation rate: 30 °C/hour | Remark: Restriction on the temperature variation rate: 30 °C/hour | Remark: Restriction on the temperature variation rate: 30 °C/hour | Remark: Restriction on the temperature variation rate: 30 °C/hour | |
Storage temperature | -40°C to 70°C | -40°C to 70°C | -40°C to 70°C | -40°C to 70°C |
Relative operating humidity | Long term: 5% to 95% RH, non-condensing | Long term: 5% to 95% RH, non-condensing | Long term: 5% to 95% RH, non-condensing | Long term: 5% to 95% RH, non-condensing |
Short term: N/A | Short term: N/A | Short term: N/A | Short term: N/A | |
Relative storage humidity | 5% to 100% RH, non-condensing | 5% to 100% RH, non-condensing | 5% to 100% RH, non-condensing | 5% to 100% RH, non-condensing |
Long-term operating altitude | ≤ 4000 meters. If the altitude is between 1800 meters and 4000 meters, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. | ≤ 4000 meters. If the altitude is between 1800 meters and 4000 meters, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. | ≤ 4000 meters. If the altitude is between 1800 meters and 4000 meters, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. | ≤ 4000 meters. If the altitude is between 1800 meters and 4000 meters, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. |
Storage altitude | Lower than 5000 meters | Lower than 5000 meters | Lower than 5000 meters | Lower than 5000 meters |
Huawei NE05E-SQ Router Product Features
- GE/10GE interfaces
- E1 interfaces
- CPOS interfaces
- Power voice interfaces
- IP FRR, LDP FRR, TE FRR, and VPN FRR
- TE-tunnel APS
- PW redundancy protection and PW APS
- Bit error-triggered protection switching
- NE08E: 1+1 hot backup for CXP boards (functioning as MPUs, SFUs, and clock boards at the same time)
- NE08E: non-stop routing (NSR)
Huawei NE05E-SQ and More Related Models
NE05E-S2
NE05E-SE
NE05E-SF
NE05E-SG
NE05E-SH
NE05E-SI
NE05E-SJ
NE05E-SK
NE05E-SL
NE05E-SM
NE05E-SN
NE05E-SQ
NE05E-SR
Huawei NE05E-SQ Product Applications
Sorry, no attachment available !