Kabel tampung MPO male-LCSCFCST Kipas untuk modul MPO LGX
- Penerangan
- Siasatan
- Lampiran
Penerangan
MPO male-LCSCFCST Fan-out patch cable for MPO LGX module is designed for high-density connections between 40GBASE-SR4 network equipment.
MPO male-LCSCFCST Fan-out patch cable for MPO LGX module Overview
The MPO connector is a type of fiber connecter. MPO (Multi-Fiber Push On) is a multi-core fiber connecter type. The MPO high -density fiber pre -connection system is currently mainly used in the application of high -density environments of data centers, the application of optical fiber to the building, and the internal connection applications inside the optical transceiver equipment such as the optical device, 40G, 100G, QSFP+. MPO connector types are distinguished according to the IEC 61754-7 regulations: core numbers (array number), male head (Male, Female), kekutuban (PC atau APC). 24F MPO- Kabel LC/SC/FC/ST Fanout 0.9mm direka untuk Penyelesaian Saling Sambung 100GBASE-SR10 CXP/CFP,100GBASE-LR4 dan pusat data berketumpatan tinggi. Ia dioptimumkan untuk aplikasi pusat data berketumpatan tinggi 10/40/100G. ini 24 Kabel abah gentian digunakan untuk menyambung (12) SFP+ ke dalam panel penyesuai MPO dan batang MPO. MPO (lelaki)-Kabel tampalan LC/SC/FC/ST Kipas keluar 0.9mm 30cm direka untuk kaset modul MPO-LC LGX ditamatkan dengan penyambung MPO dan LC/SC/FC/ST pada setiap hujung. Ia direka khusus untuk menampal gentian berketumpatan tinggi di pusat data yang memerlukan penjimatan ruang dan mengurangkan masalah pengurusan kabel.
Kabel tampalan keluar kipas MPO male-LCSCFCST untuk Modul MPO LGX Pictures
MPO male-LCSCFCST Kabel tampal kipas keluar untuk Spesifikasi modul MPO LGX
Item spesifikasi. | Singlemode (APC 8 pengilat ijazah) | Multimode (Pengilat rata PC) |
Kehilangan sisipan(MPO) | Kehilangan standard:≤0.7dB(maks) | Kehilangan standard:≤0.5dB(maks) |
Kerugian rendah:≤0.35dB(maks) | Kerugian rendah:≤0.35dB(maks) | |
Kehilangan sisipan (LC/SC/FC/ST) | ≤0.3dB | ≤0.3dB |
Pulangan kerugian(MPO) | ≥55dB | ≥35dB |
Pulangan kerugian(LC/SC/FC/ST) | APC≥60dB;UPC≥50dB | PC≥35dB |
Ketahanan | <0.3perubahan dB tipikal, 200 mengawan | |
Kebolehtukaran | ≤0.2dB | |
Kekuatan tegangan | >70N | |
Suhu Operasi | -40 kepada + 85°C |
Jenis penyambung | Item ujian | Min | Maks |
MPO PC | ROC_X(abs)(mm) | 500 | |
ROC_Y(abs)(mm) | 50 | ||
Sudut_X(deg) | -0.2 | 0.2 | |
Sudut_Y(deg) | -0.2 | 0.2 | |
Max.DH.Semua Fiber(nm) | -600 | 600 | |
Max.DH.Ave(nm) | -300 | 300 | |
Max.DH.Adj(nm) | -300 | 300 | |
Maks. Celup Teras(nm) | -300 | 300 | |
Ketinggian gentian(nm) | -300 | 300 | |
ROC_X(abs)(mm) | 1000 | 3000 | |
MPO APC | ROC_X(abs)(mm) | 500 | |
ROC_Y(abs)(mm) | 50 | ||
Sudut_X(deg) | -0.2 | 0.2 | |
Sudut_Y(deg) | 7.8 | 8.2 | |
Max.DH.Semua Fiber(nm) | -600 | 600 | |
Max.DH.Ave(nm) | -300 | 300 | |
Max.DH.Adj(nm) | -300 | 300 | |
Ketinggian gentian(nm) |
Kabel tampalan keluar kipas MPO male-LCSCFCST untuk Modul MPO LGX
- Kehilangan sisipan yang rendah, kerugian pulangan yang tinggi
- Penyambung Berbilang gentian berasaskan MT, 4,8,12 dan 24 penamatan dan pemasangan penyambung gentian
- Penyelesaian ekonomi untuk penamatan jisim gentian
- Direka untuk aplikasi SM dan MM kerugian rendah dan kerugian standard
- Kabel bulat lasak, pilihan kabel bujur dan reben kosong tersedia
- Perumah berkod warna tersedia untuk membezakan jenis gentian, jenis pengilat dan/atau gred penyambung
- Baik dalam kebolehulangan dan kebolehtukaran
Kabel tampung MPO male-LCSCFCST Fan-out untuk Aplikasi modul MPO LGX