- Apraksts
- Izziņa
- Pielikums
Apraksts
GYFFY Fiber Optic Cable is TWO FRP Aerial Fiber Optic Cable (MANA DZĪVE) according to YD/T 901-2018、GB/T13993 、IECA-596、GR-409、IEC794 and so on standard
GYFFY Fiber Optic Cable Product Overview
GYFFY Fiber Optic Cable structure is to lpput a 250μm olpptical fiber into a loose tube made of high-modulus material, and the loose tube is filled with a waterproof complex. The loose tube is sulppplemented with water-blocking material to ensure that the optical cable longitudinally blocks water, and two parallel glass fiber reinforced plastic (FRP) are placed on both sides and then extruded into a lppolyethylene sheathed cable.
Fiber olpptic transmission is based on the principle that the available light is fully reflected at the interface of the two media. Mutant olpptical fiber, n1 is the refractive index of the core medium, n2 is the refractive index of the cladding medium, n1 is greater than n2, the incidence angle of the light entering the fiber core reaches the interface between the core and the cladding layer (referred to as the core-package interface) when it is greater than the critical angle θc of total reflection, uztal reflection can occur without light energy through the fiber core, and the incident light can be transmitted forward through countless total reflections at the interface.
When the fiber is bent, the interface normal turns, and the angle of incidence is small, so the angle of incidence of a lppart of the light becomes less than θc and cannot be fully reflected. However, those rays with a large angle of incidence can still be fully reflected, so the fiber bending time can still be transmitted, but it will cause energy loss. Generally, when the bending radius is greater than 50~100 mm, its loss is negligible. Small bends can cause serious “microbending losses”.
GYFFY Fiber Optic Cable Product Pictures
GYFFY Fiber Optic Cable Specifications
G.652 | G.655 | 50/125μm | 62.5/125μm | ||
Atenuation (+20℃) | @ 850nm | ≤3.0dB/km | ≤3.0dB/km | ||
@1300nm | ≤1.0dB/km | ≤1.0dB/km | |||
@1310nm | ≤0.36dB/km | ||||
@ 1550 nm | ≤0.22dB/km | ≤0,23 dB/km | |||
Joslas platums | @850 | ≥200MHZ·km | ≥200MHZ·km | ||
(Class A) | @1300 | ≥500MHZ·km | ≥500MHZ·km | ||
Skaitliskā diafragma | 0.200±0,015NA | 0.275±0,015NA |
Cable cut-off wavelength | ≤1260 nm | ≤1480nm | |||||
Cable Core | Vienība | 2F | 4F | 6F | 8F | 10F | 12F |
Nē. Of Tubes | 1 | 1 | 1 | 1 | 1 | 1 | |
Nē. Of fibers | kodols | 2 | 4 | 6 | 9 | 10 | 12 |
Fiber Counts in tube | kodols | 2 | 4 | 6 | 9 | 10 | 12 |
Kabeļa diametrs | mm | 6.6±0.5 | 6.8±0.5 | ||||
Cable Weight | Kg/km | 40±10 | 45±10 | ||||
Allowable tensile Strength | N | Span=80,1.5*P | |||||
Allowable crush resistance | N | 1000N | |||||
Darbības temperatūra | ℃ | -20℃ to +65℃ |
GYFFY Fiber Optic Cable Product Features
- Small Size and Ligth Weight
- Two FRP as strength member to provide good tensile performance
- Gel Filled or gel free , good waterproof performance
- Low price ,high fiber capacity
- applicable for short span aerial and duct installation
- Eliminates the need for expensive cable shielding and grounding
- Uses simple attachment hardware (no preinstalled messenger)
- Outstanding cable performance and stability
GYFFY Fiber Optic Cable and More Related Cables
Iekštelpu/āra viengabala nemetāla mikro kabelis(JET)
Unitube nebruņots kabelis (GYXY)
Unitube nemetālisks bezbruņu kabelis (GYFXY)
DIVI FRP antenas optiskās šķiedras kabelis (MANA DZĪVE)
Sasprāgts, vaļīgs, nebruņots kabelis (GYTA)
Sasprāgts brīvs cauruļu gaismas bruņu kabelis (GYTS)
Sašķelts, vaļīgs bruņu kabelis (GYTY53)
Sašķelts, vaļīgs bruņu kabelis (GYTA53)
Nemetāla stiprības elementa, nebruņots kabelis (GYFTY)
Nemetālisks stiprības elements Nebruņots kabelis(KOPĀ)
Nemetāla stiprības elementu bruņu kabelis (GYFTY53)
Nemetāla stiprības elementa bruņu kabelis (GYFTA53)
Viss dielektriskais pašnesošais antenas kabelis (ADSS)
GYFFY Fiber Optic Cable Product Applications
Atvainojiet, nav pieejams pielikums !