- Descrizione
- Inchiesta
- Allegato
Descrizione
SS-OP-D-MPO12-M-15 is Optical Cable Parts,MPO/PC,MPO/PC,MULTIMODALITÀ,15M,8 NUCLEI,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,60mm MPO,Piegamento insensibile
SS-OP-D-MPO12-M-15 Product Overview
SS-OP-D-MPO12-M-15 OM3 multimode bend insensitive fiber optic cable has less attenuation when bent or twisted compared with traditional optical fiber cables and this will make the installation and maintenance of the fiber optic cables more efficient. So it can save more space for your high density cabling in data centers, reti aziendali, telecom room, server farms, cloud storage networks, eccetera., and interconnect pre-terminated cassettes in main distribution, horizontal distribution, and equipment distribution areas.
Questo 50/125 OM3 multimode fiber optic cable is ideal for connecting 10G SR, 10G LRM, SFP+ transceivers etc. for 10/40/100G Ethernet connections and is the preferred fiber specification for 10G Ethernet connections.
Optical fibers are used for carrying signals on Gigabit networks or networks with higher packet rates. An optical fiber is a carrier of optical signals and transmits optical signals over a short distance.
SS-OP-D-MPO12-M-15 Product Pictures
SS-OP-D-MPO12-M-15 Product Specifications
Tipo di connettore | MPO/UPC to MPO/UPC |
Grado di fibra | Bend Insensitive |
Conteggio delle fibre | Duplex |
Modalità fibra | OM3 50/125μm |
Lunghezza d'onda | 850/1300nm |
10G Ethernet Distance | 300m at 850nm |
Perdita di inserzione | ≤0,3 dB |
Perdita di ritorno | ≥30dB |
Min. Raggio di piegatura (Fiber Core) | 7.5mm |
Min. Raggio di piegatura (Fiber Cable) | 20/10D (Dynamic/Static) |
Attenuazione a 850nm | 3.0dB/km |
Attenuation at 1300nm | 1.0dB/km |
Cable Jacket | Riser (OFNR) |
Cable Outside Diameter (OD) | 2.0mm |
Polarità | UN (Tx) to B (Rx) |
Operating/Storage Temperature | Operating: -20 a 70°C (-4 to 158℉)
Magazzinaggio: -40 to 80℃ (-40 to 176℉) |
SS-OP-D-MPO12-M-15 and More Fiber Optic Cables
Descrizione | Numero di parte | Modello | Connettore X1 | Connettore X2 | Lunghezza del cavo | Raggio di curvatura |
Cavo di toppa,SC/PC,SC/PC,Modalità singola,5M,G.652D,3mm | 14130098 | SS-OP-D-SC-S-5 | SC/PC | SC/PC | 5 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,5M,G.652D,2mm | 14130193 | SS-OP-LC-SC-S-5 | LCD/PC | SC/PC | 5 M | 30 mm |
Cavo di toppa,LC/PC-LC/PC,Monomodale,G.652D,2mm,5M | 14130195 | SS-OP-D-LC-S-5 | LCD/PC | LCD/PC | 5 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,10M,G.652D,2mm | 14130196 | SS-OP-LC-SC-S-10 | LCD/PC | SC/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,FC/PC,Modalità singola,10M,G.652D,2mm | 14130197 | SS-OP-LC-FC-S-10 | LCD/PC | FC/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Modalità singola,10M,G.652D,2mm | 14130199 | SS-OP-D-LC-S-10 | LCD/PC | LCD/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,FC/PC,Multimodalità,10M,A1b,2mm | 14130221 | SS-OP-LC-FC-M-10 | LCD/PC | FC/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Multimodalità,10M,A1B,2mm | 14130222 | SS-OP-D-LC-M-10 | LCD/PC | LCD/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Multimodalità,10M,A1b,2mm | 14130223 | SS-OP-LC-SC-M-10 | LCD/PC | SC/PC | 10 M | 30 mm |
Adattatore ottico-LC/PC-LC/PC-Blue-Shell:Custodia in plastica:Zirconia-quadrato | 14130248 | QW1P0FIBER06 | LCD/PC | LCD/PC | – | – |
Cavo di toppa,LCD/PC,LCD/PC,Modalità singola,20M,G.652D,2mm | 14130251 | SS-OP-D-LC-S-20 | LCD/PC | LCD/PC | 20 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Multimodalità,30M,A1b,2mm | 14130275 | SS-OP-LC-SC-M-30 | LCD/PC | SC/PC | 30 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,30M,G.652D,2mm | 14130276 | SS-OP-LC-SC-S-30 | LCD/PC | SC/PC | 30 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Multimodalità,20M,A1b,2mm | 14130279 | SS-OP-LC-SC-M-20 | LCD/PC | SC/PC | 20 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,20M,G.652D,2mm | 14130280 | SS-OP-LC-SC-S-20 | LCD/PC | SC/PC | 20 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Multimodalità,20M,A1b,2mm | 14130295 | SS-OP-D-LC-M-20 | LCD/PC | LCD/PC | 20 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Multimodalità,5M,A1b,2mm | 14130296 | SS-OP-D-LC-M-5 | LCD/PC | LCD/PC | 5 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Multimodalità,50M,A1b,2mm | 14130311 | SS-OP-LC-SC-M-50 | LCD/PC | SC/PC | 50 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,50M,G.652D,2mm | 14130312 | SS-OP-LC-SC-S-50 | LCD/PC | SC/PC | 50 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Modalità singola,6M,G.652D,2mm | 14130360 | SS-OP-D-LC-S-6 | LCD/PC | LCD/PC | 6 M | 30 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,MULTIMODALITÀ,2M,8 NUCLEI,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,43MPO CORTO MM,INSENSIBILE ALLA FLESSIONE | 14130823 | F00MPMP01 | MPO/PC | MPO/PC | 2 M | 18 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,Multimodale(OM3, Insensibile alla flessione),30M,8 Nuclei,0m/0m,GJFH8A1a,3.5mm,LSZH,42mm MPO corto,Interno | 14130823-002 | FMMM03001 | MPO/PC | MPO/PC | 30 M | 17.5 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,Multimodale(OM3, Insensibile alla flessione),100M,8 Nuclei,0m/0m,GJFH8A1a,3.5mm,LSZH,42mm MPO corto,Interno | 14130823-003 | FMMM10001 | MPO/PC | MPO/PC | 100 M | 17.5 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,MULTIMODALITÀ,15M,8 NUCLEI,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,60mm MPO,Piegamento insensibile | 14130923 | SS-OP-D-MPO12-M-15 | MPO/PC | MPO/PC | 15 M | 18 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,Multimodalità,10M,8 nuclei,GJFH-8A1a.3(OM4),3.5mm,0mm,LSZH,Insensibile alla flessione | 14134486 | MPO12-MPO12-M4-10 | MPO/PC | MPO/PC | 10 M | |
LC/UPC LC/APC SC/UPC SC/APC FC/APC FC/UPC ST/UPC LSH/APC MTR/UPC G.657.A1 G.657.A2 G.652.D BIF G.651 |
SS-OP-D-MPO12-M-15 Product Applications
Scusa, nessun allegato disponibile !