Descrizione
Patch Cord SS-OP-D-LC-S-20 is Fiber Patch Cable wtth LC/PC,LCD/PC,Modalità singola,20M,G.652D,2mm
Patch Cord SS-OP-D-LC-S-20 Product Overview
Optical fiber patch cord (also known as optical fiber connector) means that connector plugs are installed at both ends of the optical cable to realize the active connection of the optical path; A plug at one end is called a pigtail. Optical Fiber Patch Cord/Cable is similar to coaxial cable, except that there is no mesh shielding. In the center is a glass core where light travels. In multimode fibers, the diameter of the core is 50μm~65μm, which is roughly the thickness of a human hair. The diameter of the single-mode fiber core is 8μm~10μm. The outside of the core is surrounded by a glass envelope with a lower refractive index than the core to keep the fiber inside the core. Outside is a thin plastic jacket to protect the envelope.
(1) FC type optical fiber jumper: the external reinforcement method is metal sleeve, and the fastening method is screw buckle. Generally used on the ODF side (most commonly used on patch panels)
(2) SC type optical fiber patch cord: the connector connected to the GBIC optical module, its shell is rectangular, and the fastening method is plug-in and unplugged pin latch, which does not need to be rotated. (Most used on routers and switches)
(3) ST type optical fiber jumper: often used in optical fiber distribution frame, the shell is round, and the fastening method is screw buckle. (For 10Base-F connections, the connector is usually ST type.) Commonly used in optical fiber distribution frames)
(4) LC type fiber optic patch cord: the connector connecting the SFP module, which is made of the easy-to-operate modular jack (RJ) latching mechanism.
Patch Cord SS-OP-D-LC-S-20 Product Pictures
Patch Cord SS-OP-D-LC-S-20 Product Specifications
Tipo di connettore | LC UPC to LC UPC |
Grado di fibra | G.657.A1 (Compatible with G.652.D) |
Modalità fibra | OS2 9/125μm |
Lunghezza d'onda | 1310/1550nm |
Perdita di inserzione | ≤0,3 dB |
Perdita di ritorno | ≥50dB |
Min. Raggio di piegatura (Fiber Core) | 10mm |
Min. Raggio di piegatura (Fiber Cable) | 10/5D (Dynamic/Static) |
Attenuation at 1310 nm | 0.36dB/km |
Attenuation at 1550 nm | 0.22dB/km |
Conteggio delle fibre | Semplice |
Cable Outside Diameter (OD) | 2.0mm |
Cable Jacket | Riser (OFNR) |
Polarità | UN (Tx) to B (Rx) |
temperatura di esercizio | -20 a 70°C (-4 to 158℉) |
Temperatura di conservazione | -40 a 80°C (-40 to 176℉) |
Patch Cord SS-OP-D-LC-S-20 Product Features
- Lightning speed: How fast is fast? Fiber optic cables can transmit data at rates up to 800 Gbps (today’s data center maximum, but theoretically rates could be even faster). Broadband internet services leverage those cables to deliver some of the fastest internet speeds to millions of customers.
- Greater bandwidth: Fiber optics can transmit a wide range of light frequencies, transferring more data at higher throughput. Per esempio, a single fiber connection can transfer a movie in HD format in less than a tenth of a second; the typical copper-wire office network would take about a minute to do the same task.
- Less data loss: Loss or attenuation is a performance measure in cabling and network standards. Optical fiber is less susceptible to data loss from electromagnetic interference from power cabling, radio signals, and even solar flares.
- Transmission over longer distances: Copper cable is limited to 100 meters in length without a signal repeater, but fiber optic cables can carry signals for 100 kilometers without losing signal strength.
Patch Cord SS-OP-D-LC-S-20 Product Applications
- Optical fiber communication system
- Optical fiber access network
- Optical fiber data transmission
- Fiber optic CATV
- Rete locale (LAN)
- Test the equipment
- Fiber optic sensor
Patch Cord SS-OP-D-LC-S-20 Product and More Fiber Cables
Descrizione | Numero di parte | Modello | Connettore X1 | Connettore X2 | Lunghezza del cavo | Raggio di curvatura |
Cavo di toppa,SC/PC,SC/PC,Modalità singola,5M,G.652D,3mm | 14130098 | SS-OP-D-SC-S-5 | SC/PC | SC/PC | 5 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,5M,G.652D,2mm | 14130193 | SS-OP-LC-SC-S-5 | LCD/PC | SC/PC | 5 M | 30 mm |
Cavo di toppa,LC/PC-LC/PC,Monomodale,G.652D,2mm,5M | 14130195 | SS-OP-D-LC-S-5 | LCD/PC | LCD/PC | 5 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,10M,G.652D,2mm | 14130196 | SS-OP-LC-SC-S-10 | LCD/PC | SC/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,FC/PC,Modalità singola,10M,G.652D,2mm | 14130197 | SS-OP-LC-FC-S-10 | LCD/PC | FC/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Modalità singola,10M,G.652D,2mm | 14130199 | SS-OP-D-LC-S-10 | LCD/PC | LCD/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,FC/PC,Multimodalità,10M,A1b,2mm | 14130221 | SS-OP-LC-FC-M-10 | LCD/PC | FC/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Multimodalità,10M,A1B,2mm | 14130222 | SS-OP-D-LC-M-10 | LCD/PC | LCD/PC | 10 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Multimodalità,10M,A1b,2mm | 14130223 | SS-OP-LC-SC-M-10 | LCD/PC | SC/PC | 10 M | 30 mm |
Adattatore ottico-LC/PC-LC/PC-Blue-Shell:Custodia in plastica:Zirconia-quadrato | 14130248 | QW1P0FIBER06 | LCD/PC | LCD/PC | – | – |
Cavo di toppa,LCD/PC,LCD/PC,Modalità singola,20M,G.652D,2mm | 14130251 | SS-OP-D-LC-S-20 | LCD/PC | LCD/PC | 20 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Multimodalità,30M,A1b,2mm | 14130275 | SS-OP-LC-SC-M-30 | LCD/PC | SC/PC | 30 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,30M,G.652D,2mm | 14130276 | SS-OP-LC-SC-S-30 | LCD/PC | SC/PC | 30 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Multimodalità,20M,A1b,2mm | 14130279 | SS-OP-LC-SC-M-20 | LCD/PC | SC/PC | 20 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,20M,G.652D,2mm | 14130280 | SS-OP-LC-SC-S-20 | LCD/PC | SC/PC | 20 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Multimodalità,20M,A1b,2mm | 14130295 | SS-OP-D-LC-M-20 | LCD/PC | LCD/PC | 20 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Multimodalità,5M,A1b,2mm | 14130296 | SS-OP-D-LC-M-5 | LCD/PC | LCD/PC | 5 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Multimodalità,50M,A1b,2mm | 14130311 | SS-OP-LC-SC-M-50 | LCD/PC | SC/PC | 50 M | 30 mm |
Cavo di toppa,LCD/PC,SC/PC,Modalità singola,50M,G.652D,2mm | 14130312 | SS-OP-LC-SC-S-50 | LCD/PC | SC/PC | 50 M | 30 mm |
Cavo di toppa,LCD/PC,LCD/PC,Modalità singola,6M,G.652D,2mm | 14130360 | SS-OP-D-LC-S-6 | LCD/PC | LCD/PC | 6 M | 30 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,MULTIMODALITÀ,2M,8 NUCLEI,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,43MPO CORTO MM,INSENSIBILE ALLA FLESSIONE | 14130823 | F00MPMP01 | MPO/PC | MPO/PC | 2 M | 18 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,Multimodale(OM3, Insensibile alla flessione),30M,8 Nuclei,0m/0m,GJFH8A1a,3.5mm,LSZH,42mm MPO corto,Interno | 14130823-002 | FMMM03001 | MPO/PC | MPO/PC | 30 M | 17.5 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,Multimodale(OM3, Insensibile alla flessione),100M,8 Nuclei,0m/0m,GJFH8A1a,3.5mm,LSZH,42mm MPO corto,Interno | 14130823-003 | FMMM10001 | MPO/PC | MPO/PC | 100 M | 17.5 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,MULTIMODALITÀ,15M,8 NUCLEI,0m/0m,GJFH-8A1A.2(OM3),3.5MM,LSZH,60mm MPO,Piegamento insensibile | 14130923 | SS-OP-D-MPO12-M-15 | MPO/PC | MPO/PC | 15 M | 18 mm |
Parti del cavo ottico,MPO/PC,MPO/PC,Multimodalità,10M,8 nuclei,GJFH-8A1a.3(OM4),3.5mm,0mm,LSZH,Insensibile alla flessione | 14134486 | MPO12-MPO12-M4-10 | MPO/PC | MPO/PC | 10 M | |
LC/UPC LC/APC SC/UPC SC/APC FC/APC FC/UPC ST/UPC LSH/APC MTR/UPC G.657.A1 G.657.A2 G.652.D BIF G.651 |
Patch Cord SS-OP-D-LC-S-20 Product Topology
Scusa, nessun allegato disponibile !