Description

Huawei TN57NS4T61 Board is 100Gbit/s Line Service Processing Board(ULH,SDFEC2,wDCM, Cohérent,Accordable,50GHz,LC)

Huawei TN57NS4T61 Board Product Overview

Huawei TN57NS4T61 Board is a trunk board that implements the relay of one OTU4 signal. NS4 uses coherent receiving technology and is applied to coherent systems.
When Huawei TN57NS4T61 Board is used as a relay board, when ESC communication is required, NS4 boards received and sent at the same wavelength must be inserted in the dual slot. There is no such limitation in other scenes.
TN57NS4: Two NS4 boards used for the same wavelength relay must be inserted in IU6 and IU8, IU10 and IU12, IU14 and IU16 respectively.
The contact position between the in-position signal line of the TN57NS4 board and the backplane is the right slot. Donc, the slot number of the NS4 board is displayed on the NMS as the right slot of the two occupied slots. Par exemple, NS4 is located in the IU1 and IU2 slots, and it is shown in the IU2 slot on the network management.

Huawei TN57NS4T61 Board Product Pictures

Huawei TN57NS4T61 Board YCICT Huawei TN57NS4T61 Board PRICE AND SPECS HUAWEI TN57NS4T61 Huawei TN57NS4T61 Board YCICT Huawei TN57NS4T61 Board PRICE AND SPECS HUAWEI NS4 NEW AND ORIGINAL

Huawei TN57NS4T61 Board PRICE AND SPECS Huawei TN57NS4T61 NEW AND ORIGINALHuawei TN57NS4T61 Board YCICT Huawei TN57NS4T61 Board PRICE AND SPECS HUAWEI WDM BOARD

Huawei TN57NS4T61 Board Product Specifications

Marque Huawei
Numéro de pièce 03030YUB
Modèle # TN57NS4T61
Description 100Carte de traitement de service de ligne Gbit/s(ULH,SDFEC2,wDCM, Cohérent,Accordable,50GHz,LC)
Poids du paquet (Kg) 5
Dimension du paquet (P*L*H mm) 39*39*27.5
Gamme de produits La mise en réseau
Famille de produits Réseau de transport
Serie de produits OSN OptiX 8800 T16

Huawei TN57NS4T61 Board Product Features

  • Provide the OTU4 interface on WDM-side.
  • Prend en charge le format de trame OTN et le traitement des frais généraux en se référant à l'ITU-T G.709.
  • ODU4 layer: supports the PM and TCM function, et fonctions de surveillance non intrusives PM et TCM.
  • Couche OTU4: supports the SM function.
  • Support ITU-T G.694.1-compliant DWDM specifications.
  • Support HFEC and SDFEC2 on the WDM side.
  • Monitor BIP8 bytes (Bursty mode) to help locate line failures.
  • Monitor parameters such as the bias current, température, and optical power of the laser.
  • Monitor OTN alarms and performance events.

Huawei TN57NS4T61 Board Product Applications

Huawei TN57NS4T61 Board YCICT Huawei TN57NS4T61 Board PRICE AND SPECS HUAWEI NS4 BOARD





    Désolé, aucune pièce jointe disponible !