Beskrivelse

Huawei NE05E-SQ Router is the cloud era ENP Based Mid Services Router, which can be flexibly applied to IP / MPLS network edge access scenarios, to meet the diverse needs of users for future business development.

Huawei NE05E-SQ Router Product Overview

Huawei NE05E-SQ Router is designed with small size, big bandwidth, and it supports for -40ºC to 65ºC working temperature range, suitable for difficult environments. The product helps transportation, finansiere, strøm, government, uddannelse, enterprise to build agile networks.
An NE device is generally located at the intersection between an enterprise’s internal network and an external network. An NE05E or NE08E is the only entrance and exit of data flows between the internal and external networks. An NE05E or NE08E can bear multiple types of services, greatly reducing network construction investment and long-term operation and maintenance costs of an enterprise network.

Huawei NE05E-SQ Router Product Pictures

Huawei NE05E-SQ Router price and specs huawei ne routerHuawei NE05E-SQ Router new and original ycict

Huawei NE08E-S6 Router NE08E&NE05E Series Control Boards ycictHuawei NE05E-SQ price and specs ycict

Huawei NE05E-SQ Router Product Specifications

Vare NE05E-SR NE05E-SQ NE08E-S6E NE08E-S9
Dimensioner (H x B x D) 43.6 mm x 250 mm x 180 mm (1.72 i. x 9.84 i. x 7.09 i.) 44.45 mm x 442 mm x 220 mm (1.75 i. x 17.40 i. x 8.66 i.) 88.90 mm x 442 mm x 220 mm (3.50 i. x 17.40 i. x 8.66 i.) 155.58 mm x 442 mm x 220 mm (6.12 i. x 17.40 i. x 8.66 i.)
Vægt (tom) N/A N/A 3.5 kg DC:7.9 kg
AC:10.3 kg
Vægt (full configuration) 1.7kg DC:4.7kg 9.17kg NEJ1CXPA DC:17.32kg
AC:4.9kg NEJ1CXPA AC:18.04kg
Skab installation standard IMB(3U), ETSI(21-tomme), IEC(19-tomme) R01S100 Outdoor Cabinet, ETSI(21-tomme), IEC(19-tomme) R01S200 Outdoor Cabinet, ETSI(21-tomme), IEC(19-tomme) R01S300A Outdoor Cabinet, ETSI(21-tomme), IEC(19-tomme)
Typisk strømforbrug AC:12.8W 2 channel DC System:82.8w 2 channel DC System, with 160G CXP Protection:111W NEJ1CXPA DC System with CXP Protection:182w
2 channel AC System:85.6w 2 channel DC System, without 160G CXP Protection:57.45W NEJ1CXPA AC System with CXP Protection:254w
AC+DC system:84.2w
Typisk varmeafledning AC:41.5BTU/time 2 channel DC System:268.6BTU/time 2 channel DC System, with 160G CXP Protection:360.1BTU/time NEJ1CXPA DC:590.4BTU/time
2 channel AC System:277.7BTU/time 2 channel DC System, without 160G CXP Protection:184.4BTU/time NEJ1CXPA AC:824.0BTU/time
AC+DC system:273.1BTU/time
DC indgangsspænding indgangsspændingsområde: 19V to 30V or -38.4V to -72V indgangsspændingsområde: -38.4V til -72V indgangsspændingsområde: -38.4V til -72V indgangsspændingsområde: -38.4V til -72V
input rated voltage: 24/-48V/-60V input rated voltage: -48V/-60V input rated voltage: -48V/-60V input rated voltage: -48V/-60V
AC indgangsspænding indgangsspændingsområde: 100 to 240V indgangsspændingsområde: 100 to 240V indgangsspændingsområde: N/A indgangsspændingsområde: 100 to 240V
input rated voltage: 110V/220V input rated voltage: 110V/220V input rated voltage: N/A input rated voltage: 110V/220V
MTBF 40 flere år 40 flere år 40 flere år 40 flere år
MTTR 2 timer 2 timer 2 timer 2 timer
Tilgængelighed 0.99999 0.99999 0.99999 0.99999
Redundante MPU'er 1+1 1+1
Overflødige fans Natural heat dissipation, no fan If a single fan fails, the system can still work for a short period of time at an ambient temperature of 50°C. If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C. If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C.
Redundant strømforsyning N/A 1+1 1+1 1+1
Skiftekapacitet 12 Gbit/s (Bidirectional) 272 Gbit/s (Bidirectional) NED3CXPA :320 Gbit/s@256 bytes (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. NEJ1CXPA :320 Gbit/s@256 bytes (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed.
NED3CXPB :320 Gbit/s@256 bytes (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed.
Driftstemperatur Long-term: -40°C to 60°C Long-term: DC:-40°C to 65°C AC:-20°C til 65 °C Long-term: DC:-40°C til 65 °C(160G) Long-term: -40°C til 65 °C
Short-term: N/A Short-term: N/A Short-term: N/A Short-term: N/A
Bemærkning: Restriction on the temperature variation rate: 30 °C/hour Bemærkning: Restriction on the temperature variation rate: 30 °C/hour Bemærkning: Restriction on the temperature variation rate: 30 °C/hour Bemærkning: Restriction on the temperature variation rate: 30 °C/hour
Stuetemperatur -40°C til 70 °C -40°C til 70 °C -40°C til 70 °C -40°C til 70 °C
Relative operating humidity Langsigtet: 5% til 95% RH, ikke-kondenserende Langsigtet: 5% til 95% RH, ikke-kondenserende Langsigtet: 5% til 95% RH, ikke-kondenserende Langsigtet: 5% til 95% RH, ikke-kondenserende
Kort sigt: N/A Kort sigt: N/A Kort sigt: N/A Kort sigt: N/A
Relative storage humidity 5% til 100% RH, ikke-kondenserende 5% til 100% RH, ikke-kondenserende 5% til 100% RH, ikke-kondenserende 5% til 100% RH, ikke-kondenserende
Langsigtet driftshøjde ≤ 4000 meter. If the altitude is between 1800 meters and 4000 meter, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. ≤ 4000 meter. If the altitude is between 1800 meters and 4000 meter, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. ≤ 4000 meter. If the altitude is between 1800 meters and 4000 meter, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude. ≤ 4000 meter. If the altitude is between 1800 meters and 4000 meter, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude.
Opbevaringshøjde Lower than 5000 meter Lower than 5000 meter Lower than 5000 meter Lower than 5000 meter

Huawei NE05E-SQ Router Product Features

  • GE/10GE interfaces
  • E1-grænseflader
  • CPOS interfaces
  • Power voice interfaces
  • IP FRR, LDP FRR, TE FRR, and VPN FRR
  • TE-tunnel APS
  • PW redundancy protection and PW APS
  • Bit error-triggered protection switching
  • NE08E: 1+1 hot backup for CXP boards (functioning as MPUs, SFU'er, and clock boards at the same time)
  • NE08E: non-stop routing (NSR)

Huawei NE05E-SQ and More Related Models

NE05E-S2
NE05E-SE
NE05E-SF
NE05E-SG
NE05E-SH
NE05E-SI
NE05E-SJ
NE05E-SK
NE05E-SL
NE05E-SM
NE05E-SN
NE05E-SQ
NE05E-SR

Huawei NE05E-SQ Product Applications

Huawei NE05E-SQ price and specs ycict





    Undskyld, ingen vedhæftet fil tilgængelig !