- Opis
- Upit
- Prilog
Opis
Huawei S12708 Switch features 4.88/16.08 Tbit/s Switching Capacity 12.32/44.96 Tbit/s Packet Forwarding Rate 2 MPU slotovi 4 SFU Slots 6 Service Card Slots
Huawei S12708 Switch Product Overview
Huawei S12708 Switch is designed for next-generation campus networks, which uses a fully programmable architecture to meet fast-changing service needs. Huawei S12708 Switch allows new services to be flexibly and quickly provisioned in six months. Huawei S12708 Switch provides high-performance Layer 2/Layer3 switching services, supports millions of hardware entries, and can meet campus network evolution over the next 10 godine. Huawei S12708 Switch has built-in large-capacity WLAN AC functionalities, achieving wired and wireless convergence and eliminating the capacity bottleneck of ACs.
Huawei S12708 Switch Product Pictures
Huawei S12708 Switch Product Specifications
Stavka | S12704 | S12708 | S12710 | S12712 |
Preklopni kapacitet | 4.88Tbps/16.08*Tbps | 12.32Tbps/44.96*Tbps | 13.12Tbps/38.56*Tbps | 17.44Tbps/44.96*Tbps |
Brzina prosljeđivanja paketa | 3, 120Mpps/4, 560*MPs | 6, 240Mpps/30, 240*MPs | 7, 440Mpps/11, 040*MPs | 9, 120Mpps/30, 240*MPs |
MPU slotovi | 2 | 2 | 2 | 2 |
SFU slots | 2 | 4 | 4 (2 integrated in MPU) | 4 |
Service card slots | 4 | 8 | 10 | 12 |
Fan slots | 2 | 4 | 4 | 5 |
Buffer size | 200ms buffer each port | |||
Redundancy design | MPUS, SFUs, napajanja, and fan modules | |||
CSS2 | 1+N backup of MPUs in a cluster | |||
Do 1.92 TBIT / S opseg klastera, 4 μs među-šasije kašnjenje prijenosa | ||||
Dimenzije (H x W x D in mm) | 441.7x442x489, 10U | 663.95x442x489, 15U | 663.95x442x489, 15U | 841.75x442x489, 19U |
Težina (empty chassis) | 24.5kg | 42kg | 28.6kg | 64kg |
Operating voltage | DC:–40V~–72V | |||
AC:90V~290V | ||||
Maximum power consumption of the entire equipment | ≤2200W | ≤4400W | ≤4400W | ≤6600W |
Huawei S12708 Switch Product Features
OPS
Otvoreni sistem programiranja (OPS) je otvoreni programabilni sistem zasnovan na jeziku Python. IT administratori mogu programirati O&M functions of a switch through Python scripts to quickly innovate functions and implement intelligent O&M.
Big data security collaboration
Agile switches use NetStream to collect campus network data and then report such data to the Huawei Cybersecurity Intelligence System (CIS). The purposes of doing so are to detect network security threats, display the security posture across the entire network, and enable automated or manual response to security threats. The CIS delivers the security policies to the Agile Controller. The Agile Controller then delivers such policies to agile switches that will handle security events accordingly. All these ensure campus network security.
Inteligentna dijagnoza
Open Intelligent Diagnosis System (OIDS) integrates the device health monitoring and fault diagnosis functions – that are typically deployed on a Network Management System (NMS) – into the switch software to implement intelligent diagnosis on a single switch. After OIDS is deployed on a switch, the switch periodically collects and records the running information and automatically determines whether a fault occurs. Ako dođe do kvara, the switch automatically locates the fault or helps locate the fault. All these merits increase fault locating efficiency of O&M staff while improving device maintainability.
Huawei S12708 Switch Product Ordering Info
LE2BN66ED000 | N66E DC montažni nosač (osam 60A izlaza, Maksimalno 2,200W po izlazu, 600 x 600 x 2,200 mm) |
LE2BN66EA000 | N66E AC montažni nosač (Četiri izlaza 16A, Maksimalno 2.500W po izlazu, 600 x 600 x 2,200 mm) |
Et1bs12704s0 | S12704 Šasija montaže |
Et1bs12708s0 | S12708 Šasija montaže |
Et1bs12710s0 | S12710 Šasija montaže |
Et1bs12712s0 | S12712 Šasija montaže |
Et1mfbx00000 | Širok napon 129 Fan Box |
EH1M00FBX000 | Širok napon 74 Fan Box |
Jedinica za nadgledanje | |
EH1D200CMU00 | Centralizovana jedinica za nadgledanje |
Glavna prerađivačka jedinica | |
Et1d2mpua000 | S12700 Glavna upravljačka jedinica A, Opcionalni sat |
Et1d2mpubc00 | S12710 Glavna upravljačka jedinica B, Opcionalni sat |
Et1d2mpubc01 | S12710, Glavna obrada B (Podržava sigurnu čizmu) |
Et1d2mpudc00 | S12704 / S12708 / S12712, Glavna prerađivačka jedinica D |
Prekidač jedinice tkanine | |
Et1d2sfua000 | S12700 Jedinica za prekidač A |
Et1d2sfub000 | S12700 Switch tkanina jedinica B |
Et1d2sfuc000 | S12700 Jedinica prekidača C |
Et1d2sfud000 | S12700 Switch Tkanina jedinica D |
100M / 1.000m Ethernet električne sučelje kartice | |
Et1d2g48tea0 | 48-luka 10/100/1,000 Base-T interfejs kartica (EA, RJ45) |
Et1d2g48tec0 | 48-luka 10/100/1,000 Base-T interfejs kartica (EC, RJ45) |
Et1d2g48tx1e | 48-luka 10/100/1,000 Base-T interfejs kartica (X1E, RJ45) |
Et1d2g48tx5s | 48-port 100/1000BASE-T interfejs kartica (X5S, RJ45) |
Et1d2g48tx5e | 48-port 100/1000BASE-T interfejs kartica (X5E, RJ45) |
Et1d2g48tx5h | 48-port 100/1000BASE-T interfejs kartica (X5H, RJ45) |
100M / 1.000m Ethernet optički sučelje | |
Et1d2g24sec0 | 24-luka 100/1,000 Base-X Interface kartica (EC, SFP) |
Et1d2g24sx5e | 24-port 100/1000BASE-X interfejs kartica (X5E, SFP) |
Et1d2g48sea0 | 48-luka 100/1,000 Base-X Interface kartica (EA, SFP) |
Et1d2g48sec0 | 48-luka 100/1,000 Base-X Interface kartica (EC, SFP) |
Et1d2g48sx1e | 48-luka 100/1,000 Base-X Interface kartica (X1E, SFP) |
Et1d2g48sx5s | 48-port 100/1000BASE-X interfejs kartica (X5S, SFP) |
Et1d2g48sx5e | 48-port 100/1000BASE-X interfejs kartica (X5E, SFP) |
Et1d2g48sx5h | 48-port 100/1000BASE-X interfejs kartica (X5H, SFP) |
100M / 1.000m Ethernet električne i optičke sučelje kartice Ethernet | |
Et1d2t36sea0 | 36-luka 10/100/1000 Base-T i 12-port 100/1000 Base-X Interface kartica (EA, RJ45 / SFP) |
10 GE Optičke kartice sučelja | |
Et1d2s04sx1e | 4-Port 10g Base-X i 24-port 100/1000 Base-X i 8-port 10/100/1000 Base-T Combo Interface kartica (X1E, RJ45/SFP/SFP+) |
Et1d2s04sx5e | 4-port 10GE SFP+ i 44-port GE SFP interfejs kartica (X5E, SFP+) |
Et1d2s08sx1e | 8-Port 10g Base-X i 8-port 100/1000 Base-X i 8-port 10/100/1000 Base-T Combo Interface kartica (X1E, RJ45/SFP/SFP+) |
Et1d2x08sx5e | 8-port 10GE SFP+ interfejs kartica (X5E, SFP+) |
Et1d2x08sx5h | 8-port 10GE SFP+ interfejs kartica (X5H, SFP+) |
Et1d2x16sssc2 | 16-Port 10GBASE-X Interfejs kartica(SC, SFP+) |
Et1d2x32sssc0 | 32-Port 10GBASE-X Interfejs kartica(SC, SFP+) |
Et1d2x48sec00 | 48-Port 10G base-x interfejs kartica (EC, SFP+) |
Et1d2x32sx2h | 32-Port 10GE SFP+ Interface Card(X2h, SFP+) |
Et1d2x32sx2s | 32-Port 10GE SFP+ Interface Card(X2S, SFP+) |
Et1d2x32sx2e | 32-Port 10GE SFP+ Interface Card(X2E, SFP+) |
Et1d2s24sx2s | 24-Port 10ge SFP + sučelje i 8-port GE SFP interfejs kartica(X2S, SFP+) |
Et1d2s24sx2e | 24-Port 10ge SFP + sučelje i 8-port GE SFP interfejs kartica(X2E, SFP+) |
Et1d2s16sx2s | 16-Port 10ge SFP + sučelje i 16-port GE SFP interfejs kartica(X2S, SFP+) |
Et1d2s16sx2e | 16-Port 10ge SFP + sučelje i 16-port GE SFP interfejs kartica(X2E, SFP+) |
Et1d2x48sx2s | 48-Port 10GE SFP+ Interface Card(X2S, SFP+) |
40 GE Optičke kartice sučelja | |
Et1d2l02qc00 | 2-Port 40g Base-X Interface kartica (SC, QSFP+) |
Et1d2l08qc00 | 8-Port 40g Base-X Interface kartica (SC, QSFP+) |
Eh1d2l08qx2e | 8-Port 40 GE QSFP + Interface kartica (X2E, QSFP+) |
Et1d2l16qx2h | 16-Port 40 GE QSFP + Interface kartica (X2h, QSFP+) |
100 GE Optičke kartice sučelja | |
Et1d2c02fee0 | 2-Port 100g Base-X Interface kartica(Od,CFP) |
Et1d2c04hx2h | 4-Port 100 GE QSFP28 INTERFACE kartica (X2h, QSFP28) |
Et1d2c04hx2s | 4-Port 100 GE QSFP28 INTERFACE kartica (X2S, QSFP28) |
Et1d2c04hx2e | 4-Port 100 GE QSFP28 INTERFACE kartica (X2E, QSFP28) |
Et1d2c08hx2h | 8-Port 100 GE QSFP28 INTERFACE kartica (X2h, QSFP28) |
Et1d2h02qx2s | 2-Port 100 GE QSFP28 sučelje i 2-port 40 GE QSFP + Interface kartica (X2S, QSFP28) |
Et1d2h02qx2e | 2-Port 100 GE QSFP28 sučelje i 2-port 40 GE QSFP + Interface kartica (X2E, QSFP28) |
Servisne podnačevine | |
Eh1d2vs08000 | 8-Port 10g Servisna jedinica za prebacivanje klastera (SFP+) |
Et1d2vq06000 | 6-Port 40 GE klaster Servisna jedinica za prebacivanje (QSFP+) |
LE0D00CKMA00 | Sat Pinch Board-1588 |
Kartice za preradu usluga | |
Et1d2fw00s00 | NGFW modul a, Sa softverom za opću sigurnosnu platformu HW |
Et1d2fw00s01 | NGFW modul B, Sa softverom za opću sigurnosnu platformu HW |
Et1d2fw00s02 | NGFW modul C, Sa softverom za opću sigurnosnu platformu HW |
Et1d2ips0s00 | IPS modul a, Sa softverom za opću sigurnosnu platformu HW |
AUC2 | WLAN ACU2 Uređaj za kontrolu pristupa (128 Uključen CONTROL RESERSE) |
Optički primopredajnici | |
Fe-SFP optički primopredajnik | |
SFP-FE-SX-MM1310 | Optički primopredajnik, SFP, 100M / 155m, Multi-modul modul (1,310 nm, 2 km, LC) |
ESFP-FE-LX-SM1310 | Optički primopredajnik, eSFP, 100M / 155m, Modul s jednim načinom (1,310 nm, 15 km, LC) |
S-SFP-FE-LH40-SM1310 | Optički primopredajnik, eSFP, FE, Modul s jednim načinom (1,310 nm, 40 km, LC) |
S-SFP-FE-LH80-SM1550 | Optički primopredajnik, eSFP, FE, Modul s jednim načinom (1,550 nm, 80 km, LC) |
Ge-SFP optički primopredajnik | |
SFP-1000Baset | Bakar primopredajnik, SFP, GE, Električni interfejs modul (100m, RJ45) |
ESFP-GE-SX-MM850 | Optički primopredajnik, eSFP, GE, Multimodni modul (850 nm, 0.5 km, LC) |
SFP-GE-LX-SM1310 | Optički primopredajnik, SFP, GE, Modul s jednim načinom (1,310 nm, 10 km, LC) |
S-SFP-GE-LH40-SM1310 | Optički primopredajnik, eSFP, GE, Modul s jednim načinom (1,310 nm, 40 km, LC) |
S-SFP-GE-LH40-SM1550 | Optički primopredajnik, eSFP, GE, Modul s jednim načinom (1,550 nm, 40 km, LC) |
S-SFP-GE-LH80-SM1550 | Optički primopredajnik, eSFP, GE, Modul s jednim načinom (1,550 nm, 80 km, LC) |
ESFP-GE-ZX100-SM1550 | Optički primopredajnik, eSFP, GE, Modul s jednim načinom (1,550 nm, 100 km, LC) |
10 GE-XFP optički primopredajnik | |
Xfp-sx-mm850 | Optički primopredajnik, XFP, 10G, Multimodni modul (850 nm, 0.3 km, LC) |
XFP-STM64-LX-SM1310 | Optički primopredajnik, XFP, 10G, Modul s jednim načinom (1,310 nm, 10 km, LC) |
XFP-STM64-LH40-SM1550 | Optički primopredajnik, XFP, 10G, Modul s jednim načinom (1,550 nm, 40 km, LC) |
XFP-STM64-SM1550-80 km | Optički primopredajnik, XFP, 10G, Modul s jednim načinom (1,550 nm, 80 km, LC) |
10 GE-SFP + optički primopredajnik | |
OMXD30000 | Optički primopredajnik, SFP+, 10G, Multimodni modul (850 nm, 0.3 km, LC) |
OSX010000 | Optički primopredajnik, SFP+, 10G, Modul s jednim načinom (1,310 nm, 10 km, LC) |
OSX040N01 | Optički primopredajnik, SFP+, 10G, Modul s jednim načinom (1,550 nm, 40 km, LC) |
OSXD22N00 | Optički primopredajnik, SFP+, 10G, Modul s jednim načinom (1,310 nm, 0.22km, LC, Lrm) |
SFP-10G-USR | Optički primopredajnik, SFP+, 10G, Multimodni modul (850 nm, 0.1 km, LC) |
SFP-10G-ZR | Optički primopredajnik, SFP+, 10G, Modul s jednim načinom (1,550 nm, 80 km, LC) |
SFP-10G-ZCW1571 | Optički primopredajnik, SFP+, 10G, Modul s jednim načinom (CWDM, 1,571 nm, 70 km, LC) |
SFP-10G-ZCW1591 | Optički primopredajnik, SFP+, 10G, Modul s jednim načinom (CWDM, 1,591 nm, 70 km, LC) |
SFP-10G-ZCW1611 | Optički primopredajnik, SFP+, 10G, Modul s jednim načinom (CWDM, 1,611 nm, 70 km, LC) |
SFP-10G-iLR | Optički primopredajnik, SFP+, 10G, Modul s jednim načinom (DWDM, 1560.61-1529.16nm, 60km, LC) |
SFP-10G-ZDWT-L | Optički primopredajnik, SFP+, 9.8G, Modul s jednim načinom (1,310 nm, 1.4 km, LC) |
40 GE optički primopredajnici | |
QSFP-40G-iSR4 | 40G Base-ISR4 optički primopredajnik, QSFP, 40G, Multimodni modul (850 nm, 0.15 km, MPO) (Povezivanje na četiri SFP + optički primopredajnici) |
Qsfp-40g-lx4 | 40G Base-LX4 optički primopredajnik, QSFP+, 40 GE, Single-mode (1,310 nm, 2 km, LC), Multi-mode (1,310 nm, 0.15 km, LC) |
QSFP-40G-ISM4 | 40G Base-ism4 optički primopredajnik, QSFP+, 40G, Modul s jednim načinom (1,310 nm, 1.4 km, MPO) (Povezivanje na četiri SFP + optički primopredajnici) |
QSFP-40G-eSM4 | 40G Base-ESM4 optički primopredajnik, QSFP+, 40G, Modul s jednim načinom (,1310 nm, 10 km, MPO) (Povezivanje na četiri SFP + optički primopredajnici) |
QSFP-40G-LR4 | 40G Base-LR4 optički primopredajnik, QSFP+, 40G, Modul s jednim načinom (1,310 nm, 10 km, LC) |
QSFP-40G-eSR4 | 40G Base-ESR4 optički primopredajnik, QSFP+, 40G, Multimodni modul (850 nm, 0.3 km, MPO) (Povezivanje na četiri SFP + optički primopredajnici) |
CFP-40G-SR4 | Primopredajnik velike brzine, CFP, 40G, Multimodni modul (850 nm, 4 x 10g, 0.1 km, MPO) |
CFP-40G-LR4 | Primopredajnik velike brzine, CFP, 40G, Modul s jednim načinom (1,310 nm bend, 41.25G, 10 km, Stright LC) |
CFP-40G-ER4 | Primopredajnik velike brzine, CFP, 40G, Modul s jednim načinom (1,310 nm bend, 41.25G, 40 km, Stright LC) |
CFP-40G-ZR4 | Primopredajnik velike brzine, CFP,40G, Modul s jednim načinom (1,550 nm bend, 41.25G, 80 km, Stright LC) |
QSFP-40G-ER4 | 40G Base-ER4 optički primopredajnik, QSFP+, 40G, Modul s jednim načinom (1,310 nm, 40 km, LC) |
100 GE optički primopredajnici | |
CFP-100G-SR10 | Primopredajnik velike brzine, CFP, 100G, Multimodni modul (850 nm, 10 x 10g, 0.1 km, MPO) (može se povezati 10 SFP + portovi ili 2 QSFP + portovi) |
CFP-100G-LR4 | Primopredajnik velike brzine, CFP, 100G, Modul s jednim načinom (1,310 nm bend, 4 x 25g, 10 km, Stright LC) |
CFP-100G-ER4 | Primopredajnik velike brzine, CFP, 100G, Modul s jednim načinom (1,310 nm bend, 4 x 25g, 40 km, Stright LC) |
CFP-100GE-ZR4 | 100G baza,CFP modul, 100G, Modul s jednim načinom (1,310 nm bend, 4 x 25g, 80 km, Stright LC) |
QSFP-100G-CLR4 | Primopredajnik velike brzine, QSFP28, 1,310 nm, 4 x 25g baza, -6.5 dBm, 2.5 dBm, -10.7 dBm, LC/PC, 2 km |
QSFP-100G-CWDM4 | Primopredajnik velike brzine, QSFP28, 1,310 nm, 4 x 25g baza, -6.5 dBm, 2.5 dBm, -9.8 dBm, LC/PC, 2 km |
QSFP-100G-ER4-Lite | 100G Base-ER4-Lite optički primopredajnik, QSFP28, 100G, Jednomodni modul (1,310 nm, 30 km (FEC OFF), 40 km (FEC ON), LC) |
QSFP-100G-LR4 | 100G Base-LR4 optički primopredajnik, QSFP28, 100G, Jednomodni modul (1,310 nm, 10 km, LC) |
QSFP-100G-SR4 | 100G Base-SR4 Optički primopredajnik, QSFP28, 100G, Multi-mode (850 nm, 0.1 km, MPO) |
QSFP-100G-PSM4 | 100G Base-PSM4 optički primopredajnik, QSFP28, 100G, Jednomodni modul (1,310 nm, 0.5 km, MPO) |
Bidi-SFP optički primopredajnici | |
SFP-FE-LX-SM1310-BIDI | Optički primopredajnik, eSFP, FE, Bidiy Jedinstveni modul (TX1310 / RX1550, 15 km, LC) |
SFP-FE-LX-SM1550-BIDI | Optički primopredajnik, eSFP, FE, Bidiy Jedinstveni modul (TX1550 / RX1310, 15 km, LC) |
SFP-GE-LX-SM1310-BIDI | Optički primopredajnik, eSFP, GE, Bidiy Jedinstveni modul (TX1310 / RX1490,10 KM, LC) |
SFP-GE-LX-SM1490-BIDI | Optički primopredajnik, eSFP, GE, Bidiy Jedinstveni modul (TX1490 / RX1310,10 KM, LC) |
Le2mgsc40ed0 | Optički primopredajnik, SFP, GE, Bidiy Jedinstveni modul (TX1490/RX1310, 40 km, LC) |
Le2mgsc40de0 | Optički primopredajnik, SFP, GE, Bidiy Jedinstveni modul (TX1310/RX1490, 40 km, LC) |
SFP-GE-ZBXD1 | Optički primopredajnik, eSFP, GE, Bidiy Jedinstveni modul (TX1570 / RX1490, 80 km, LC) |
Sfp-ge-zbxu1 | Optički primopredajnik, eSFP, GE, Bidiy Jedinstveni modul (TX1490 / RX1570, 80 km, LC) |
BEDI-SFP + optički primopredajnici | |
SFP-10G-ER-SM1330-BIDI | Optički primopredajnik, SFP+, 10G, Bidiy Jedinstveni modul (TX1330 / RX1270, 40 km, LC) |
SFP-10G-ER-SM1270-BIDI | Optički primopredajnik, SFP+, 10G, Bidiy Jedinstveni modul (TX1270 / RX1330, 40 km, LC) |
SFP-10G-BXU1 | 10G baza, Dvosmjerni (Bidi) optički primopredajnik, SFP, 10G, Modul s jednim načinom (TX1270 / RX1330, 10 km, LC) |
SFP-10G-BXD1 | 10G baza, Bidijski optički primopredajnik, SFP, 10G, Modul s jednim načinom (TX1330 / RX1270, 10 km, LC) |
Kabl velike brzine | |
SFP-10G-CU1M | SFP +, 10g, Velike brzine direktnih kablova, 1m, SFP + 20M, Cc2p0.255b(S), SFP + 20M, koristi u zatvorenom prostoru |
SFP-10G-CU3M | SFP+, 10G, Velike brzine direktnih kablova, 3m, SFP + 20M, Cc2p0.255b(S), SFP + 20M, koristi u zatvorenom prostoru |
SFP-10G-CU5M | SFP, 10G, Kabl velike brzine, 5m, SFP + 20M, Cc2p0.255b(S), SFP + 20M, LSFRZH za u zatvorenom prostoru |
SFP-10G-AC10M | SFP+, 10G, Aktivni kablovi velike brzine, 10m, SFP + 20M, Cc2p0.32b(S), SFP + 20M, koristi u zatvorenom prostoru |
QSFP-4SFP10G-CU1M | QSFP+, 4SFP + 10G, Velike brzine direktnih kablova, 1m, QSFP + 38M, CC8P0.2544b(S), 4 x SFP + 20M, koristi u zatvorenom prostoru |
QSFP-4SFP10G-CU3M | QSFP+, 4SFP + 10G, Velike brzine direktnih kablova, 3m, QSFP + 38M, Cc8p0.32b(S), 4 x SFP + 20M, koristi u zatvorenom prostoru |
QSFP-4SFP10G-CU5M | QSFP+, 4SFP + 10G, Velike brzine direktnih kablova, 5m, QSFP + 38M, CC8P0.4B(S), 4 x SFP + 20M, koristi u zatvorenom prostoru |
QSFP-40G-CU1M | QSFP+, 40G, Velike brzine direktnih kablova, 1m, QSFP + 38M, CC8P0.2544b(S), QSFP + 38M, koristi u zatvorenom prostoru |
QSFP-40G-CU3M | QSFP+, 40G, Velike brzine direktnih kablova, 3m, QSFP + 38M, Cc8p0.32b(S), QSFP + 38M, koristi u zatvorenom prostoru |
Qsfp-40g-cu5m | QSFP+, 40G, Velike brzine direktnih kablova, 5m, QSFP + 38M, Cc8p0.40b(S), QSFP + 38M, koristi u zatvorenom prostoru |
QSFP-100G-CU1M | Kabl velike brzine, 100G QSFP28 Pasivni kabl velike brzine, 1m, QSFP28, CC8P0.2544b(S), QSFP28, Eth 100 Nositi |
QSFP-100G-CU3M | Kabl velike brzine, 100G QSFP28 Pasivni kabl velike brzine, 3m, QSFP28, CC8P0.2544b(S), QSFP28, Eth 100 Nositi |
QSFP-100G-CU5M | Kabl velike brzine, 100G QSFP28 Pasivni kabl velike brzine, 5m, QSFP28, CC8P0.4B(S), QSFP28, Eth 100 Nositi |
Optička vlakna | |
SFP-10G-AOC3M | AOC optički primopredajnik, SFP+, 850 nm, 1G do 10g, 0.003 km |
SFP-10G-AOC10M | AOC optički primopredajnik, SFP+, 850 nm, 1G do 10g, 10m |
QSFP-H40G-AOC10M | Optički primopredajnik, QSFP+, 40G, (850 nm, 10m, AOC) |
Qsfp-4sfp10-aoc10m | Optički primopredajnik, QSFP+, 40G, (850 nm, 10m, AOC) (Povezivanje na četiri SFP + optički primopredajnici) |
QSFP-100G-AOC10M | Primopredajnik velike brzine, Qsfp28 na QSFP28 AOC, 850 nm, 100G, 0.01 km |
Moduli napajanja | |
Pac-2200WF | 2,200W AC modul za napajanje |
PDC-2200WF | 2,200W DC modul za napajanje |
W2psa0800 | 800W AC Power Module (crna) |
Softver | |
Et1sm28000 | Softver S12700 V200R008C00 |
Et1sbsm2a000 | S12700 V200R010C00 softver |
Et1sbsm2b010 | Softver S12700 V200R011C10 |
Et1sbsm2c000 | Softver S12700 V200R012C00 |
Et1sbsm2d000 | S12700 V200R013C00 Mainframe softver |
Licenca | |
Et1smps0000 | MPLS licenca za funkciju |
Et1snqa00000 | Ponesite licencu funkcije |
Et1sipv60000 | IPV6 licenca za funkciju |
Et1ssvff0000 | SVF licenca funkcije (Primjenjivo samo na S12700 seriju) |
Et1svxlan000 | Vxlan poboljšana licenca funkcije(koristi se u seriji S12700) |
Et1fib128k0 | X-serija LPU FIB Resource Licenca-128K |
Et1fib512k0 | X-serija LPU FIB resursa licence-512K |
Et1swl512ap0 | WLAN pristupni kontroler Ap Resource License-512AP (Sa korištenim LPU serije X-Series) |
Et1swl128ap0 | WLAN pristupni kontroler AP Resource Licence-128AP (Sa korištenim LPU serije X-Series) |
Et1swl64ap00 | WLAN pristupni kontroler AP Resource Licence-64AP (Sa korištenim LPU serije X-Series) |
Et1swl16ap00 | WLAN pristupni kontroler AP Resource Licence-16AP (Sa korištenim LPU serije X-Series) |
L-ACU2-128AP | ACU2 Wireless Access Controller Ap Resource Licenca (128 AP) |
L-ACU2-256AP | ACU2 Wireless Access Controller Ap Resource Licenca (256 AP) |
L-ACU2-384AP | ACU2 Wireless Access Controller Ap Resource Licenca (384 AP) |
L-ACU2-512AP | ACU2 Wireless Access Controller Ap Resource Licenca (512 AP) |
Dokumentacija | |
Et1iv2rdc0e0 | S12700 serija Agilni prekidači V200R013C00 Dokumentacija proizvoda |
Huawei S12708 Switch Product Applications